On 31 May 2018 at 08:05, Lorenzo Bianconi <[email protected]> wrote:
> Do not send Neighbor Discovery packets to conntrack module if > load balancing rules have been added to NB db since otherwise > Neighbor Advertisement frames will be discarded by OVN. > In order to reproduce the issue it is enough to add 2 logical ports > to a single logical switch, assign an IPv6 address to each VIF, and > define a load balance rule on the logical switch. After a while the > ping6 from VIF1 to VIF2 will stop since the vm will not receive any NA > packet > > Signed-off-by: Lorenzo Bianconi <[email protected]> > --- > ovn/northd/ovn-northd.c | 6 ++++++ > 1 file changed, 6 insertions(+) > > diff --git a/ovn/northd/ovn-northd.c b/ovn/northd/ovn-northd.c > index 0e06776ad..aa9298d3b 100644 > --- a/ovn/northd/ovn-northd.c > +++ b/ovn/northd/ovn-northd.c > @@ -2977,6 +2977,12 @@ ls_has_dns_records(const struct > nbrec_logical_switch *nbs) > static void > build_pre_lb(struct ovn_datapath *od, struct hmap *lflows) > { > + /* Do not send ND packets to conntrack */ > + ovn_lflow_add(lflows, od, S_SWITCH_IN_PRE_LB, 110, > + "nd || nd_rs || nd_ra", "next;"); > + ovn_lflow_add(lflows, od, S_SWITCH_OUT_PRE_LB, 110, > + "nd || nd_rs || nd_ra", "next;"); > + > /* Allow all packets to go to next tables by default. */ > ovn_lflow_add(lflows, od, S_SWITCH_IN_PRE_LB, 0, "1", "next;"); > ovn_lflow_add(lflows, od, S_SWITCH_OUT_PRE_LB, 0, "1", "next;"); > You will need to document this change in 'man ovn-northd' in the section 'LOGICAL FLOW TABLE STRUCTURE'. > -- > 2.14.3 > > _______________________________________________ > dev mailing list > [email protected] > https://mail.openvswitch.org/mailman/listinfo/ovs-dev > _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev