On Tue, Apr 09, 2019 at 12:37:48PM -0400, [email protected] wrote: > From: Tonghao Zhang <[email protected]> > > In some case, we may not use the openvswitch tc to limit the ingress > police rate. And before we add the port to openvswitch bridge, we may > set the ingress policer, so don't remove the ingress when we not configured > it in openvswitch. > > Signed-off-by: Tonghao Zhang <[email protected]> > --- > lib/netdev-linux.c | 23 ++++++++++++++--------- > 1 file changed, 14 insertions(+), 9 deletions(-) > > diff --git a/lib/netdev-linux.c b/lib/netdev-linux.c > index 0fce217..ad8a244 100644 > --- a/lib/netdev-linux.c > +++ b/lib/netdev-linux.c > @@ -2448,6 +2448,7 @@ netdev_linux_set_policing(struct netdev *netdev_, > const char *netdev_name = netdev_get_name(netdev_); > int ifindex; > int error; > + bool should_cleanup_ingress = false; > > kbits_burst = (!kbits_rate ? 0 /* Force to 0 if no rate specified. > */ > : !kbits_burst ? 8000 /* Default to 8000 kbits if 0. */ > @@ -2466,14 +2467,10 @@ netdev_linux_set_policing(struct netdev *netdev_, > /* Assume that settings haven't changed since we last set them. > */ > goto out; > } > + should_cleanup_ingress = true; > netdev->cache_valid &= ~VALID_POLICING; > } > > - error = get_ifindex(netdev_, &ifindex); > - if (error) { > - goto out; > - } > - > COVERAGE_INC(netdev_set_policing); > > /* Use matchall for policing when offloadling ovs with tc-flower. */
Thanks for working on this. This new version uses the logic that if and only if there's a cached policing setting, then OVS must have set it up, and only in that case should OVS clean it up. But the assumption is wrong. The setting cache is just a cache and it gets reset if the kernel notifies us of a change to a device. It also doesn't persist from one OVS run to another, so this wouldn't allow OVS to turn off policing if it set it and then segfaulted and restarted (or the admin stopped and started it). _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev