On 25.10.2019 17:55, William Tu wrote:
On Fri, Oct 25, 2019 at 4:44 AM Ilya Maximets <[email protected]> wrote:There is a race window between getting the time and getting the meter lock. This could lead to situation where the thread with larger current time (this thread called time_{um}sec() later than others) will acquire meter lock first and update meter->used to the large value. Next threads will try to calculate time delta by subtracting the large meter->used from their lower time getting the negative value which will be converted to a big unsigned delta. Fix that by assuming that all these threads received packets in the same time in this case, i.e. dropping negative delta to 0. CC: Jarno Rajahalme <[email protected]> Fixes: 4b27db644a8c ("dpif-netdev: Simple DROP meter implementation.") Reported-at: https://mail.openvswitch.org/pipermail/ovs-dev/2019-September/363126.html Signed-off-by: Ilya Maximets <[email protected]> ---LGTM. Thanks for the fix Acked-by: William Tu <[email protected]>
Thanks, William! Applied to master and backported. Best regards, Ilya Maximets. _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev