If the offloading queue is big and filled continuously, offloading
thread may have no chance to quiesce blocking rcu callbacks and
other threads waiting for synchronization.

Fix that by entering momentary quiescent state after each operation
since we're not holding any rcu-protected memory here.

Fixes: 02bb2824e51d ("dpif-netdev: do hw flow offload in a thread")
Reported-by: Eli Britstein <[email protected]>
Reported-at: 
https://mail.openvswitch.org/pipermail/ovs-discuss/2020-February/049768.html
Signed-off-by: Ilya Maximets <[email protected]>
---
 lib/dpif-netdev.c | 1 +
 1 file changed, 1 insertion(+)

diff --git a/lib/dpif-netdev.c b/lib/dpif-netdev.c
index d393aab5e..a798db45d 100644
--- a/lib/dpif-netdev.c
+++ b/lib/dpif-netdev.c
@@ -2512,6 +2512,7 @@ dp_netdev_flow_offload_main(void *data OVS_UNUSED)
         VLOG_DBG("%s to %s netdev flow\n",
                  ret == 0 ? "succeed" : "failed", op);
         dp_netdev_free_flow_offload(offload);
+        ovsrcu_quiesce();
     }
 
     return NULL;
-- 
2.24.1