On 5/7/20 5:54 PM, Aaron Conole wrote:
> It's possible that port ordering could cause the block ID to change
> after enabling / detecting TC Flower support. Therefore, fetch the
> block_id again after probing.
>
> Fixes: edc2055a2bf7 ("netdev-offload-tc: Flush rules on ingress block when
> init tc flow api")
> Cc: Dmytro Linkin <[email protected]>
> Co-authored-by: Marcelo Leitner <[email protected]>
> Signed-off-by: Marcelo Leitner <[email protected]>
> Signed-off-by: Aaron Conole <[email protected]>
> ---
> lib/netdev-offload-tc.c | 1 +
> 1 file changed, 1 insertion(+)
>
> diff --git a/lib/netdev-offload-tc.c b/lib/netdev-offload-tc.c
> index 875ebef719..8864555d01 100644
> --- a/lib/netdev-offload-tc.c
> +++ b/lib/netdev-offload-tc.c
> @@ -1939,6 +1939,7 @@ netdev_tc_init_flow_api(struct netdev *netdev)
> ovsthread_once_done(&multi_mask_once);
> }
>
> + block_id = get_block_id_from_netdev(netdev);
This is not obvious from the code why we're fetching block id twice.
Maybe we could move this right after probing and add the comment?
Something like:
if (ovsthread_once_start(&block_once)) {
probe_tc_block_support(ifindex);
/* Need to re-fetch block id since it depends on feature availability.
*/
block_id = get_block_id_from_netdev(netdev);
ovsthread_once_done(&block_once);
}
What do you think?
Best regards, Ilya Maximets.