With ovn-monitor-all=true all chassis get updates about all SB DB records regardless if they're of interest to the local chassis or not.
There's a bug in the IGMP code in ovn-controller which causes IGMP_Group records not owned by the local chassis to be flushed. The second patch in this series fixes the issue. The first patch propagates the value of ovn-monitor-all to the Chassis:other_config field in order to make unit tests that use ovn-monitor-all more reliable. CC: Han Zhou <[email protected]> Signed-off-by: Dumitru Ceara <[email protected]> Dumitru Ceara (2): chassis: Propagate ovn-monitor-all external-id to Chassis:other_config. pinctrl: Avoid flushing of non-local IGMP_Groups. controller/chassis.c | 23 +++++++++++++++++++++-- controller/pinctrl.c | 10 ++++++++++ tests/ovn.at | 51 +++++++++++++++++++++++++++++++++++++++++++++++++- 3 files changed, 81 insertions(+), 3 deletions(-) _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev