The commit c99069c8934c ("ovn-controller: Provide the option to configure
inactivity probe interval for OpenFlow conn") supports configuring probe
interval for the openflow connection of ofctrl module. However, it changed the
default behavior. The default OpenFlow connection probe was defaults to 0
(disabled), because the connection is always unix socket (to local OVS br-int
bridge). After that patch it changed to probe every 5 seconds, which was not
the intension.
This patch restores the default behavior of disabling the probe by setting
default value to 0, while keeping the capability of letting user configure it.
Cc: Numan Siddique <[email protected]>
Signed-off-by: Han Zhou <[email protected]>
---
controller/ovn-controller.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/controller/ovn-controller.c b/controller/ovn-controller.c
index 5ca32ac..c383cf3 100644
--- a/controller/ovn-controller.c
+++ b/controller/ovn-controller.c
@@ -76,7 +76,7 @@ static unixctl_cb_func cluster_state_reset_cmd;
#define DEFAULT_BRIDGE_NAME "br-int"
#define DEFAULT_PROBE_INTERVAL_MSEC 5000
-#define OFCTRL_DEFAULT_PROBE_INTERVAL_SEC 5
+#define OFCTRL_DEFAULT_PROBE_INTERVAL_SEC 0
#define CONTROLLER_LOOP_STOPWATCH_NAME "ovn-controller-flow-generation"
--
2.1.0