Hi Dumitru, I have corrected the patch format and resubmitted it. Please check it.
Thanks, Gongming > On Feb 7, 2021, at 12:25 AM, gmingchen(陈供明) <[email protected]> wrote: > > From: Gongming Chen <[email protected]> > > After setting the iface-id, immediately check the up status of the port > binding, it will occasionally fail, especially when the port binding > status is reported later. > > When it fails, the following will be output: > Checking values in sb Port_Binding with logical_port=lsp1 against false... > found false > ovs-vsctl add-port br-int lsp1 -- set Interface lsp1 > external-ids:iface-id=lsp1 > ./ovn-macros.at:307: "$@" > Checking values in sb Port_Binding with logical_port=lsp1 against true... > found false > _uuid : 15ebabb6-3dbb-4806-aa85-d1c03e3b39f6 > logical_port : lsp1 > up : true > ./ovn-macros.at:393: hard failure > > Fixes: 4d3cb42b076b ("binding: Set Logical_Switch_Port.up when all OVS flows > are installed.") > Signed-off-by: Gongming Chen <[email protected]> > --- > tests/ovn.at | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) > > diff --git a/tests/ovn.at b/tests/ovn.at > index 80c9fe138..43dc16dd8 100644 > --- a/tests/ovn.at > +++ b/tests/ovn.at > @@ -23885,7 +23885,7 @@ check ovn-nbctl --wait=hv sync > check_column "false" Port_Binding up logical_port=lsp1 > > check ovs-vsctl add-port br-int lsp1 -- set Interface lsp1 > external-ids:iface-id=lsp1 > -check_column "true" Port_Binding up logical_port=lsp1 > +wait_column "true" Port_Binding up logical_port=lsp1 > wait_column "true" nb:Logical_Switch_Port up name=lsp1 > OVS_WAIT_UNTIL([test `ovs-vsctl get Interface lsp1 > external_ids:ovn-installed` = '"true"']) > > -- > 2.23.0 > _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev