This optimization caused FLOW_TNL_F_UDPIF flag not to be used in hash calculation for geneve tunnel when revalidating flows which resulted in different cache hash values and incorrect behaviour.
Added test to prevent regression. Reported-at: https://github.com/vmware-tanzu/antrea/issues/897 Signed-off-by: Toms Atteka <cpp.code...@gmail.com> --- lib/tun-metadata.c | 2 +- tests/system-traffic.at | 54 +++++++++++++++++++++++++++++++++++++++++ 2 files changed, 55 insertions(+), 1 deletion(-) diff --git a/lib/tun-metadata.c b/lib/tun-metadata.c index c0b0ae044..828db72f5 100644 --- a/lib/tun-metadata.c +++ b/lib/tun-metadata.c @@ -828,7 +828,7 @@ tun_metadata_to_geneve_nlattr(const struct flow_tnl *tun, } else { tun_metadata_to_geneve_nlattr_mask(key, tun, flow, b); } - } else if (flow->metadata.present.len || is_mask) { + } else { nl_msg_put_unspec(b, OVS_TUNNEL_KEY_ATTR_GENEVE_OPTS, tun->metadata.opts.gnv, flow->metadata.present.len); diff --git a/tests/system-traffic.at b/tests/system-traffic.at index fb5b9a36d..483cc7e83 100644 --- a/tests/system-traffic.at +++ b/tests/system-traffic.at @@ -574,6 +574,60 @@ NS_CHECK_EXEC([at_ns0], [ping -s 3200 -q -c 3 -i 0.3 -w 2 10.1.1.100 | FORMAT_PI OVS_TRAFFIC_VSWITCHD_STOP AT_CLEANUP +AT_SETUP([datapath - ping over geneve tunnel, delete flow regression]) +OVS_CHECK_GENEVE() + +OVS_TRAFFIC_VSWITCHD_START() +ADD_BR([br-underlay]) + +AT_DATA([flows.txt], [dnl +priority=100,icmp actions=resubmit(,10) +priority=0 actions=NORMAL +table=10, priority=100, ip, actions=ct(table=20,zone=65520) +table=20, priority=200, ip, ct_state=-new+trk, actions=resubmit(,30) +table=20, priority=100, ip, ct_state=+new, actions=resubmit(,30) +table=20, priority=50, ip, actions=DROP +table=30, priority=100, ip, actions=ct(commit,table=40,zone=65520) +table=40, actions=normal +]) + +AT_CHECK([ovs-ofctl add-flows br0 flows.txt]) +AT_CHECK([ovs-ofctl add-flow br-underlay "actions=normal"]) + +ADD_NAMESPACES(at_ns0) + +dnl Set up underlay link from host into the namespace using veth pair. +ADD_VETH(p0, at_ns0, br-underlay, "172.31.1.1/24") +AT_CHECK([ip addr add dev br-underlay "172.31.1.100/24"]) +AT_CHECK([ip link set dev br-underlay up]) + +dnl Set up tunnel endpoints on OVS outside the namespace and with a native +dnl linux device inside the namespace. +ADD_OVS_TUNNEL([geneve], [br0], [at_gnv0], [172.31.1.1], [10.1.1.100/24]) +ADD_NATIVE_TUNNEL([geneve], [ns_gnv0], [at_ns0], [172.31.1.100], [10.1.1.1/24], + [vni 0]) + +dnl First, check the underlay +NS_CHECK_EXEC([at_ns0], [ping -q -c 3 -i 0.3 -w 2 172.31.1.100 | FORMAT_PING], [0], [dnl +3 packets transmitted, 3 received, 0% packet loss, time 0ms +]) + +dnl ping over tunnel should work +NS_CHECK_EXEC([at_ns0], [ping -q -c 3 -i 0.3 -w 2 10.1.1.100 | FORMAT_PING], [0], [dnl +3 packets transmitted, 3 received, 0% packet loss, time 0ms +]) + +AT_CHECK([ovs-ofctl del-flows br0 "ct_state=+new"]) + +dnl ping should not go through after removal of the flow +NS_CHECK_EXEC([at_ns0], [ping -q -c 3 -i 0.3 -w 2 10.1.1.100 | FORMAT_PING], [0], [dnl +7 packets transmitted, 0 received, 100% packet loss, time 0ms +]) + +OVS_TRAFFIC_VSWITCHD_STOP(["/|ERR|/d +/|WARN|/d"]) +AT_CLEANUP + AT_SETUP([datapath - flow resume with geneve tun_metadata]) OVS_CHECK_GENEVE() -- 2.25.1 _______________________________________________ dev mailing list d...@openvswitch.org https://mail.openvswitch.org/mailman/listinfo/ovs-dev