On 04/06/2021 16:03, Dumitru Ceara wrote:
> On 6/4/21 4:50 PM, Mark Gray wrote:
>> On 03/06/2021 16:05, Dumitru Ceara wrote:
>>> This ensures the datapath type is properly set for the bridge.
>>
>> I don't understand how this causes a problem? Can you provide additional
>> context?
> 
> br-int and br-ex are patched together by ovn-controller.  They must have
> the same datapath type.  I.e., it won't work if br-int uses the netdev
> (userspace) datapath and br-ext uses the system (kernel) datapath;
> system is the default.
> 
> If you think it would help I can update the commit message in v2.

Yeah that would help.

Thanks
> 
> Thanks,
> Dumitru
> 

_______________________________________________
dev mailing list
[email protected]
https://mail.openvswitch.org/mailman/listinfo/ovs-dev