To allow for use of optional plugging support we add a new plugged_by column with weakRef to the Chassis table. The ovn-controller can monitor this column and only process events for its chassis UUID.
ovn-northd will fill this column with UUID of Chassis referenced in Logical_Switch_Port options:requested-chassis when options:plug-type is defined. Signed-off-by: Frode Nordahl <[email protected]> --- northd/ovn-northd.c | 31 ++++++++++++++++++++++++++++++ ovn-nb.xml | 38 ++++++++++++++++++++++++++++++++++++ ovn-sb.ovsschema | 10 +++++++--- ovn-sb.xml | 15 +++++++++++++++ tests/ovn-northd.at | 47 +++++++++++++++++++++++++++++++++++++++++++++ 5 files changed, 138 insertions(+), 3 deletions(-) diff --git a/northd/ovn-northd.c b/northd/ovn-northd.c index 4c164a744..3ab296081 100644 --- a/northd/ovn-northd.c +++ b/northd/ovn-northd.c @@ -3164,6 +3164,35 @@ ovn_port_update_sbrec(struct northd_context *ctx, * ha_chassis_group cleared in the same transaction. */ sbrec_port_binding_set_ha_chassis_group(op->sb, NULL); } + + const char *plug_type; /* May be NULL. */ + const char *requested_chassis; /* May be NULL. */ + bool reset_plugged_by = false; + plug_type = smap_get(&op->nbsp->options, "plug-type"); + requested_chassis = smap_get(&op->nbsp->options, + "requested-chassis"); + if (plug_type && requested_chassis) { + const struct sbrec_chassis *chassis; /* May be NULL. */ + chassis = chassis_lookup_by_name(sbrec_chassis_by_name, + requested_chassis); + if (chassis) { + sbrec_port_binding_set_plugged_by(op->sb, chassis); + } else { + reset_plugged_by = true; + static struct vlog_rate_limit rl = VLOG_RATE_LIMIT_INIT( + 1, 1); + VLOG_WARN_RL( + &rl, + "Unknown chassis '%s' set as " + "options:requested-chassis on LSP '%s'.", + requested_chassis, op->nbsp->name); + } + } else if (op->sb->plugged_by) { + reset_plugged_by = true; + } + if (reset_plugged_by) { + sbrec_port_binding_set_plugged_by(op->sb, NULL); + } } else { const char *chassis = NULL; if (op->peer && op->peer->od && op->peer->od->nbr) { @@ -14901,6 +14930,8 @@ main(int argc, char *argv[]) add_column_noalert(ovnsb_idl_loop.idl, &sbrec_port_binding_col_nat_addresses); ovsdb_idl_add_column(ovnsb_idl_loop.idl, &sbrec_port_binding_col_chassis); + ovsdb_idl_add_column(ovnsb_idl_loop.idl, + &sbrec_port_binding_col_plugged_by); ovsdb_idl_add_column(ovnsb_idl_loop.idl, &sbrec_port_binding_col_gateway_chassis); ovsdb_idl_add_column(ovnsb_idl_loop.idl, diff --git a/ovn-nb.xml b/ovn-nb.xml index c1176e81f..d2cf3a984 100644 --- a/ovn-nb.xml +++ b/ovn-nb.xml @@ -1020,6 +1020,44 @@ DHCP reply. </p> </column> + + <group title="VIF Plugging Options"> + <p> + These options apply to logical ports with + <ref column="options" key="requested-chassis"/> and + <ref column="options" key="plug-type"/> set. + </p> + + <column name="options" key="plug-type"> + If set, OVN will attempt to to perform plugging of this VIF. In + order to get this port plugged by the OVN controller, OVN must be + built with support for VIF plugging. The default behavior is for + the CMS to do the VIF plugging. + Supported values: representor + </column> + + <column name="options" key="plug-pf-mac"> + MAC address for identifying PF device. When + <ref column="options" key="plug-vf-num"/> is also set, this + option is used to identify PF to use as base to locate the correct + VF representor port. When + <ref column="options" key="plug-vf-num"/> is not set this + option is used to locate a PF representor port. + </column> + + <column name="options" key="plug-vf-num"> + Logical VF number relative to PF device specified in + <ref column="options" key="plug-pf-mac"/>. + </column> + + <column name="options" key="plug-mtu-request"> + Requested MTU for plugged interfaces. When set the OVN controller + will fill the <ref table="Interface" column="mtu_request"/> column + of the Open vSwitch database's + <ref table="Interface" db="vswitch"/> table. This in turn will + make OVS vswitchd update the MTU of the linked interface. + </column> + </group> </group> <group title="Virtual port Options"> diff --git a/ovn-sb.ovsschema b/ovn-sb.ovsschema index e5ab41db9..4df326ff4 100644 --- a/ovn-sb.ovsschema +++ b/ovn-sb.ovsschema @@ -1,7 +1,7 @@ { "name": "OVN_Southbound", - "version": "20.20.0", - "cksum": "605270161 26670", + "version": "20.21.0", + "cksum": "888060012 26935", "tables": { "SB_Global": { "columns": { @@ -232,7 +232,11 @@ "external_ids": {"type": {"key": "string", "value": "string", "min": 0, - "max": "unlimited"}}}, + "max": "unlimited"}}, + "plugged_by": {"type": {"key": {"type": "uuid", + "refTable": "Chassis", + "refType": "weak"}, + "min": 0, "max": 1}}}, "indexes": [["datapath", "tunnel_key"], ["logical_port"]], "isRoot": true}, "MAC_Binding": { diff --git a/ovn-sb.xml b/ovn-sb.xml index f3b6307e3..281334cbc 100644 --- a/ovn-sb.xml +++ b/ovn-sb.xml @@ -2983,6 +2983,21 @@ tcp.flags = RST; </dd> </dl> </column> + <column name="plugged_by"> + Chassis that should plug this port, this column must be a + <ref table="Chassis"/> record. This is populated by + <code>ovn-northd</code> when the <ref + table="Logical_Switch_Port" + column="options" + key="requested-chassis" + db="OVN_Northbound"/> and <ref + table="Logical_Switch_Port" + column="options" + key="plug-type" + db="OVN_Northbound"/> is defined. In order to get this port plugged by + the OVN controller, OVN must be built with support for VIF plugging. + The default behavior is for the CMS to do the VIF plugging. + </column> </group> <group title="Patch Options"> diff --git a/tests/ovn-northd.at b/tests/ovn-northd.at index d4d3c9b65..27a530833 100644 --- a/tests/ovn-northd.at +++ b/tests/ovn-northd.at @@ -5029,3 +5029,50 @@ AT_CHECK([grep -e "lr_in_ip_routing_ecmp" lr0flows | sed 's/192\.168\.0\..0/192. AT_CLEANUP ]) + +OVN_FOR_EACH_NORTHD([ +AT_SETUP([check requested-chassis and plug-type fills plugged_by col]) +AT_KEYWORDS([plugging]) +ovn_start NORTHD_TYPE + +# Add chassis ch1. +check ovn-sbctl chassis-add ch1 geneve 127.0.0.2 +check ovn-sbctl chassis-add ch2 geneve 127.0.0.3 +check ovn-sbctl chassis-add ch3 geneve 127.0.0.4 + +wait_row_count Chassis 3 + +ch1_uuid=`ovn-sbctl --bare --columns _uuid find Chassis name="ch1"` +ch2_uuid=`ovn-sbctl --bare --columns _uuid find Chassis name="ch2"` +ch3_uuid=`ovn-sbctl --bare --columns _uuid find Chassis name="ch3"` + +ovn-nbctl ls-add S1 +ovn-nbctl --wait=sb lsp-add S1 S1-vm1 + +ovn-nbctl --wait=sb set logical_switch_port S1-vm1 \ + options:requested-chassis=ch1 + +wait_row_count Port_Binding 1 logical_port=S1-vm1 plugged_by!=$ch1_uuid + +ovn-nbctl --wait=sb set logical_switch_port S1-vm1 \ + options:plug-type=representor + +wait_row_count Port_Binding 1 logical_port=S1-vm1 plugged_by=$ch1_uuid + +ovn-nbctl --wait=sb set logical_switch_port S1-vm1 \ + options:requested-chassis=ch2 options:plug-type=representor + +wait_row_count Port_binding 1 logical-port=S1-vm1 plugged_by=$ch2_uuid + +ovn-nbctl --wait=sb set logical_switch_port S1-vm1 \ + options:requested-chassis=ch3 options:plug-type=representor + +wait_row_count Port_binding 1 logical-port=S1-vm1 plugged_by=$ch3_uuid + +ovn-nbctl --wait=sb remove logical_switch_port S1-vm1 \ + options plug-type=representor + +wait_row_count Port_binding 1 logical-port=S1-vm1 plugged_by!=$ch3_uuid + +AT_CLEANUP +]) -- 2.31.1 _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev