On Fri, Aug 13, 2021 at 6:56 PM Han Zhou <[email protected]> wrote: > > The extra get_local_datapath() call seems unnecessary. Remove it and > combine the two if-blocks to an if-else block. > > Signed-off-by: Han Zhou <[email protected]>
I did the scale testing with these patches and it showed great improvements in the number of OF flows and CPU usage of ovn-controllers. For the patches - 2 to 6 Acked-by: Numan Siddique <[email protected]> Thanks Numan > --- > controller/binding.c | 13 ++++--------- > 1 file changed, 4 insertions(+), 9 deletions(-) > > diff --git a/controller/binding.c b/controller/binding.c > index 2a10d7586..aa032789c 100644 > --- a/controller/binding.c > +++ b/controller/binding.c > @@ -2386,15 +2386,10 @@ delete_done: > b_ctx_out->local_datapaths, > b_ctx_out->tracked_dp_bindings); > } > - > - ld = get_local_datapath(b_ctx_out->local_datapaths, > - pb->datapath->tunnel_key); > - } > - > - /* Add the peer datapath to the local datapaths if it's > - * not present yet. > - */ > - if (ld) { > + } else { > + /* Add the peer datapath to the local datapaths if it's > + * not present yet. > + */ > add_local_datapath_peer_port( > pb, b_ctx_in->sbrec_datapath_binding_by_key, > b_ctx_in->sbrec_port_binding_by_datapath, > -- > 2.30.2 > > _______________________________________________ > dev mailing list > [email protected] > https://mail.openvswitch.org/mailman/listinfo/ovs-dev > _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev