On Tue, Nov 2, 2021 at 12:40 PM Dumitru Ceara <[email protected]> wrote:
>
> On 11/2/21 2:31 PM, Frode Nordahl wrote:
> > The ovn-controller requested-chassis localport test currently
> > makes a change to the NB DB with --wait=sb, and subsequently does
> > an immediate check for change on a chassis.  This does not allways
> > succeed.
> >
> > Update the test to use `--wait=hv` instead.
> >
> > Fixes: ad77db239d9a ("controller: Make use of 
> > Port_Binding:requested_chassis.")
> > Signed-off-by: Frode Nordahl <[email protected]>
> > ---
>
> Hi Frode,
>
> This looks good to me, thanks!
>
> Acked-by: Dumitru Ceara <[email protected]>

Thanks.   Applied.

Numan

>
> Regards,
> Dumitru
>
> _______________________________________________
> dev mailing list
> [email protected]
> https://mail.openvswitch.org/mailman/listinfo/ovs-dev
>
_______________________________________________
dev mailing list
[email protected]
https://mail.openvswitch.org/mailman/listinfo/ovs-dev

Reply via email to