On Fri, Nov 5, 2021 at 7:00 AM Frode Nordahl <[email protected]> wrote: > > Introduce infrastructure for VIF plug providers and add feature to > ovn-controller to add and remove ports on the integration bridge as > directed by CMS through Logical_Switch_Port options. > > Traditionally it has been the CMSs responsibility to create Virtual > Interfaces (VIFs) as part of instance (Container, Pod, Virtual > Machine etc.) life cycle, and subsequently manage plug/unplug > operations on the Open vSwitch integration bridge. > > With the advent of NICs connected to multiple distinct CPUs we can > have a topology where the instance runs on one host and Open > vSwitch and OVN runs on a different host, the smartnic control plane > CPU. The host facing interfaces will be visible to Open vSwitch > and OVN as representor ports. > > The actions necessary for plugging and unplugging the representor > port in Open vSwitch running on the smartnic control plane CPU would > be the same for every CMS. > > Hardware or platform specific details for initialization and lookup > of representor ports is provided by an plugging provider hosted > inside or outside the core OVN repository, and linked at OVN build > time. > > RFC1 -> RFC2: > - Introduce the plug-provider interface, remove hardware/platform > dependent code. > - Add ovsport module. > - Integrate with binding module. > - Split into multiple patches. > > RFC2 -> v1: > - Extend build system, `--with-plug-provider`. > - Check for required data in b_ctx_in and lbinding data structures. > - Split consider_plug_lport into update and create processing > functions. > - Consider unplug on release where relevant. > - Add ovn-controller `--enable-dummy-plug` option for testing. > - Consistent function naming and move ovsport module to controller/. > - Rename plug-test.c -> plug-dummy.c. > - Add functional- and unit- tests. > > v1 -> v2: > - Move update to controller/binding.h from patch 6 -> patch 5. > - Fix lint problems reported by 0-day Robot. > > v2 -> v3: > - Fix build system extension for plug provider. > - Implement DDlog version of northd change. > - Rebase on tip. > > v3 -> v4: > - sb:Port_Binding:plugged_by -> sb:Port_Binding:requested_chassis. > - Move documentation of plugin specific options to plugin > implementation. > - ovn-northd-ddlog: squash changes into same patch as C version, rework > the DDlog implementation. > - controller: Use requested_chassis column instead of parsing options. > - plug-provider: Remove the extra class instantiation layer and > refcounting. Add documentation and various tweaks. > - controller: Add engine node for plug provider so that a plugin run > function can run at an appropriate time and also allow feeding back > information about changes that can not be handled incrementally. > - binding: Fix return values for plug functions so they adhere to the > incremental processing engine contract. > - Add support for building in-tree plug providers. > > v4 -> v5: > - binding: Make some data structures and functions public to allow > other modules to make use of its local binding tracking data > structures. > - Add separate incremental processing engine nodes for the plug > provider. > - Do change handling in the controller/plug module rather than piggy > backing on the binding module. > - Deal with asynchronous notification to plug provider class and > subsequent freeing of data structures when the transaction commits. > - Drop the representor plugin as in-tree plugin to address concerns about > it being Linux-only and having netlink/kernel dependencies. Will > upstream to ovn-org/ovn-vif instead. > > v5 -> v6: > - Fix 0-day Robot documentation lexer warning treated as error: > https://mail.openvswitch.org/pipermail/ovs-build/2021-September/017538.html > > v6 -> v7: > - lport: Fall back to strcmp when requested-chassis option is set > but Port_Binding->requested_chassis is not filled yet. > - physical: Make use of common lport_can_bind_on_this_chassis helper > instead of duplicating the inverse check in the code. > - tests: Add test cases to cover currently uncovered requested-chassis > functionality. > - plug: Make smaps struct members instead of pointers. > - plug: Don't use is_deleted function when not iterating over tracked > records. Avoid adding multiple delete or update iface requests > to the same transaction. > - plug: For full recompute, don't process until northd has populated > Port_Binding->requested_chassis to avoid thrashing on startup. > Also fix order of processing. > - plug: Handle failed transactions appropriately. > - tests: Clean up and extend plug test case. > > v7 -> v8: > - Patches 1 through 9 from v7 was merged. > - Use Port_Binding:requested_chassis index when iterating over PBs. > - Drop separate I-P engine nodes for the VIF plug providers at this > time, we can revisit the need for it in the event of VIF plug > providers gaining support for Scalable Functions and the increased > density that entails. > - Rename module, objects and folders from 'plug-' to 'vif-plug-*' to > avoid using too generic names. > - Don't call vif_plug_port_ctx_destroy on vif_plug_port_prepare > failure, make the convention that plug provider should clean up after > itself in that case. > - Simplify the unplug/plug thrashing avoidance on startup with a rather > naive counter to ensure IDL has data prior to attempting any > processing. Once we identify the root of the issue this can be removed. > > v8 -> v9: > - Amend comment with inaccurate statements about behavior of tracked > data. > - Increase the IDL prime counter and reset it whenever the OVNSB DB > reconnects. > - Don't add indexes not used by I-P as inputs to the I-P engine. > - Update NEWS statement. > - Fix Documentation path reference in ovn-architecture.7.xml > > v9 -> v10: > - Move creation of indexes from patch 2 -> patch 3 > > Previous discussion: > - RFC1: https://patchwork.ozlabs.org/project/ovn/patch/[email protected]/ > - RFC2: https://patchwork.ozlabs.org/project/ovn/cover/[email protected]/ > > Frode Nordahl (4): > lib: Add infrastructure for VIF plug providers. > ovn-controller: Prepare VIF plug provider infrastructure. > controller: Consider plugging VIF on CMS request. > NEWS: Add note on infrastructure for VIF plug providers. > > Documentation/automake.mk | 2 + > Documentation/topics/index.rst | 1 + > .../topics/vif-plug-providers/index.rst | 32 + > .../vif-plug-providers/vif-plug-providers.rst | 209 ++++++ > NEWS | 6 + > acinclude.m4 | 49 ++ > configure.ac | 2 + > controller/automake.mk | 4 +- > controller/ovn-controller.c | 81 ++- > controller/test-vif-plug.c | 72 ++ > controller/vif-plug.c | 634 ++++++++++++++++++ > controller/vif-plug.h | 80 +++ > lib/automake.mk | 10 +- > lib/vif-plug-provider.c | 204 ++++++ > lib/vif-plug-provider.h | 163 +++++ > lib/vif-plug-providers/dummy/vif-plug-dummy.c | 120 ++++ > ovn-architecture.7.xml | 35 +- > ovn-nb.xml | 21 + > tests/automake.mk | 13 +- > tests/ovn-macros.at | 2 +- > tests/ovn-vif-plug.at | 8 + > tests/ovn.at | 121 ++++ > 22 files changed, 1851 insertions(+), 18 deletions(-) > create mode 100644 Documentation/topics/vif-plug-providers/index.rst > create mode 100644 Documentation/topics/vif-plug-providers/vif-plug-providers.rst > create mode 100644 controller/test-vif-plug.c > create mode 100644 controller/vif-plug.c > create mode 100644 controller/vif-plug.h > create mode 100644 lib/vif-plug-provider.c > create mode 100644 lib/vif-plug-provider.h > create mode 100644 lib/vif-plug-providers/dummy/vif-plug-dummy.c > create mode 100644 tests/ovn-vif-plug.at > > -- > 2.32.0 >
Thanks Frode! I applied the series to the main branch with a minor comment update in patch1, see below. I didn't want to bother you for another round of patches for this, so hope it's fine. Thanks for Numan's reviews for the previous versions as well, and I added his acks except for the last patch which was added after his ack for the series. Regards, Han ----------------------------------------------------------------------------------------------------------------------------------- diff --git a/controller/vif-plug.c b/controller/vif-plug.c index 1015a4c13..62b75263c 100644 --- a/controller/vif-plug.c +++ b/controller/vif-plug.c @@ -526,10 +526,11 @@ vif_plug_handle_iface(const struct ovsrec_interface *iface_rec, } /* On initial startup or on IDL reconnect, several rounds of the main loop may - * run before data is actually loaded in the IDL. This situation is currently - * not reflected in a call to ovsdb_idl_has_ever_connected(). Until we find - * the root of this issue we need this counter so that we do not erronously - * unplug ports because the data is just not loaded yet. + * run before data is actually loaded in the IDL, primarily depending on + * conditional monitoring status and other events that could trigger main loop + * runs during this period. Until we find a reliable way to determine the + * completeness of the initial data downloading we need this counter so that we + * do not erronously unplug ports because the data is just not loaded yet. */ #define VIF_PLUG_PRIME_IDL_COUNT_SEEED 10 static int vif_plug_prime_idl_count = VIF_PLUG_PRIME_IDL_COUNT_SEEED; _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev