Hi,

is seems like I found a regression with a latest ovn main branch code using 
ovn-ic.
My setup utilises ramp switches (ovn-controller-vtep), so some chassis have 
vxlan encap.
But I guess the problem affects non-vtep switch VXLAN installations too.
OVN IC transit switches use tunnel key ids > OVN_MAX_DP_KEY_LOCAL 
(OVN_MAX_DP_KEY - OVN_MAX_DP_GLOBAL_NUM)
so if user has at least one VXLAN-enabled chassis and interconnected
with transit switch LRs he/she will get in northd logs lots of next messages:

2021-11-08T21:03:32.606Z|00132|northd|WARN|Tunnel key 16711897 for datapath 
vpc-6A0E5C34-global is incompatible with VXLAN
2021-11-08T21:04:32.607Z|00133|northd|WARN|Dropped 27 log messages in last 60 
seconds (most recently, 31 seconds ago) due to excessive rate

In commit [1] this logic was introduced. I can’t understand from the code and 
from commit itself
if previous behaviour can be supported, but maybe I’m missing something.
Can somebody help on this please?

Thanks.

1: 
https://github.com/ovn-org/ovn/commit/fd44d75959cedcedf1f103173be1d9fa1abd9cb8

Regards,
Vladislav Odintsov

_______________________________________________
dev mailing list
[email protected]
https://mail.openvswitch.org/mailman/listinfo/ovs-dev