On Tue, Dec 6, 2022 at 9:56 AM Dumitru Ceara <[email protected]> wrote: > > On 12/6/22 15:52, Frode Nordahl wrote: > > If a OVN deployment has OVN RBAC enabled for the southbound > > database, enabling BFD would lead to permission errors. > > > > The data in the entries in the BFD table do not belong to any > > given chassis and no column can provide authentication, but the > > rules still need to be there for successful operation. > > > > Fixes: 117203584d98 ("controller: introduce BFD tx path in ovn-controller.") > > Reported-at: https://bugs.launchpad.net/ubuntu/+source/ovn/+bug/1995771 > > Signed-off-by: Frode Nordahl <[email protected]> > > --- > > Looks good to me, thanks! > > Acked-by: Dumitru Ceara <[email protected]>
Thanks applied to main and branch-22.12. I'll backport until 22.03 soon. Thanks Numan > > _______________________________________________ > dev mailing list > [email protected] > https://mail.openvswitch.org/mailman/listinfo/ovs-dev > _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev