The test was often failing with a meter of 10 pps while generating 100 packets. When the 100 packets generation takes more than 100 msec, the test fails. This happens from time to time in upstream ci. Reducing the number of generated packets to 40 should reduce number of flakes.
Signed-off-by: Xavier Simonart <[email protected]> --- tests/system-ovn.at | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/tests/system-ovn.at b/tests/system-ovn.at index b46f67636..3ede60f0a 100644 --- a/tests/system-ovn.at +++ b/tests/system-ovn.at @@ -7190,7 +7190,7 @@ NS_EXEC([sw01], [tcpdump -l -n -i sw01 icmp -Q in > reject.pcap &]) check ovn-nbctl --may-exist meter-add acl-meter drop 10 pktps 0 ip netns exec sw01 scapy -H <<-EOF p = IP(src="192.168.1.2", dst="192.168.1.1") / UDP(dport = 12345) / Raw(b"X"*64) -send (p, iface='sw01', loop = 0, verbose = 0, count = 100) +send (p, iface='sw01', loop = 0, verbose = 0, count = 40) EOF # 10pps -- 2.31.1 _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev