On Thu, Dec 12, 2024 at 04:52:38PM +0100, Felix Huettner via dev wrote:
> previously we prevented using the routing-protocol-redirect option on
> chassis-redirect ports. However the option works fine there, therefor we
> remove the limitation.
>
> Signed-off-by: Felix Huettner <[email protected]>
Recheck-request: github-robot-_ovn-kubernetes
> ---
> NEWS | 2 +
> northd/northd.c | 8 ---
> tests/system-ovn.at | 152 +++++++++++++++++++++++++++++++++++++++++++-
> 3 files changed, 153 insertions(+), 9 deletions(-)
>
> diff --git a/NEWS b/NEWS
> index 264549817..2c39676cc 100644
> --- a/NEWS
> +++ b/NEWS
> @@ -8,6 +8,8 @@ Post v24.09.0
> removed in the next release.
> - The LRP option 'centralize_routing' has been removed. The behavior is
> now
> enabled in all cases where it is needed.
> + - The experimental logical router port options "routing-protocol-redirect"
> + and "routing-protocols" are now also useable on distributed gateway
> ports.
>
> OVN v24.09.0 - 13 Sep 2024
> --------------------------
> diff --git a/northd/northd.c b/northd/northd.c
> index 3cc8afc05..41f6f22d1 100644
> --- a/northd/northd.c
> +++ b/northd/northd.c
> @@ -14427,14 +14427,6 @@ build_lrouter_routing_protocol_redirect(
> return;
> }
>
> - if (op->cr_port) {
> - static struct vlog_rate_limit rl = VLOG_RATE_LIMIT_INIT(1, 5);
> - VLOG_WARN_RL(&rl, "Option 'routing-protocol-redirect' is not "
> - "supported on Distributed Gateway Port '%s'",
> - op->key);
> - return;
> - }
> -
> /* Ensure that LSP, to which the routing protocol traffic is redirected,
> * exists. */
> struct ovn_port *lsp_in_peer = ovn_port_find(ls_ports,
> diff --git a/tests/system-ovn.at b/tests/system-ovn.at
> index e5b1fd43c..fc7a2f0d5 100644
> --- a/tests/system-ovn.at
> +++ b/tests/system-ovn.at
> @@ -13904,7 +13904,7 @@ AT_CLEANUP
> ])
>
> OVN_FOR_EACH_NORTHD([
> -AT_SETUP([Routing protocol redirect])
> +AT_SETUP([Routing protocol redirect - l3 gateway])
> AT_SKIP_IF([test $HAVE_NC = no])
>
> ovn_start
> @@ -14052,6 +14052,156 @@ OVS_TRAFFIC_VSWITCHD_STOP(["/.*error receiving.*/d
> AT_CLEANUP
> ])
>
> +OVN_FOR_EACH_NORTHD([
> +AT_SETUP([Routing protocol redirect - DGP])
> +AT_SKIP_IF([test $HAVE_NC = no])
> +
> +ovn_start
> +OVS_TRAFFIC_VSWITCHD_START()
> +
> +ADD_BR([br-int])
> +ADD_BR([br-ext])
> +
> +check ovs-ofctl add-flow br-ext action=normal
> +# Set external-ids in br-int needed for ovn-controller
> +check ovs-vsctl \
> + -- set Open_vSwitch . external-ids:system-id=hv1 \
> + -- set Open_vSwitch .
> external-ids:ovn-remote=unix:$ovs_base/ovn-sb/ovn-sb.sock \
> + -- set Open_vSwitch . external-ids:ovn-encap-type=geneve \
> + -- set Open_vSwitch . external-ids:ovn-encap-ip=169.0.0.1 \
> + -- set bridge br-int fail-mode=secure
> other-config:disable-in-band=true
> +
> +# Start ovn-controller
> +start_daemon ovn-controller
> +
> +check ovn-nbctl lr-add R1
> +
> +check ovn-nbctl ls-add public
> +check ovn-nbctl ls-add bar
> +
> +check ovn-nbctl lrp-add R1 rp-public 00:00:02:01:02:03 172.16.1.1/24
> +check ovn-nbctl lrp-add R1 rp-bar 00:00:ff:00:00:01 192.168.10.1/24
> +
> +check ovn-nbctl lsp-add public public-rp -- set Logical_Switch_Port
> public-rp \
> + type=router options:router-port=rp-public \
> + -- lsp-set-addresses public-rp router
> +
> +check ovn-nbctl lsp-add bar bar-rp -- set Logical_Switch_Port bar-rp \
> + type=router options:router-port=rp-bar \
> + -- lsp-set-addresses bar-rp router
> +
> +check ovn-nbctl lsp-add public bgp-daemon \
> + -- lsp-set-addresses bgp-daemon unknown
> +
> +check ovn-nbctl lrp-set-gateway-chassis rp-public hv1
> +
> +# Setup container "bar1" representing host on an internal network
> +ADD_NAMESPACES(bar1)
> +ADD_VETH(bar1, bar1, br-int, "192.168.10.2/24", "00:00:ff:ff:ff:01", \
> + "192.168.10.1")
> +check ovn-nbctl lsp-add bar bar1 \
> + -- lsp-set-addresses bar1 "00:00:ff:ff:ff:01 192.168.10.2"
> +
> +# Setup SNAT for the internal host
> +check ovn-nbctl lr-nat-add R1 snat 172.16.1.1 192.168.10.2
> +
> +# Configure external connectivity
> +check ovs-vsctl set Open_vSwitch .
> external-ids:ovn-bridge-mappings=phynet:br-ext
> +check ovn-nbctl lsp-add public public1 \
> + -- lsp-set-addresses public1 unknown \
> + -- lsp-set-type public1 localnet \
> + -- lsp-set-options public1 network_name=phynet
> +
> +check ovn-nbctl --wait=hv sync
> +
> +# Set option that redirects BGP and BFD traffic to a LSP "bgp-daemon"
> +check ovn-nbctl --wait=sb set logical_router_port rp-public
> options:routing-protocol-redirect=bgp-daemon
> +check ovn-nbctl --wait=sb set logical_router_port rp-public
> options:routing-protocols=BGP,BFD
> +
> +# Create "bgp-daemon" interface in a namespace with IP and MAC matching LRP
> "rp-public"
> +ADD_NAMESPACES(bgp-daemon)
> +ADD_VETH(bgp-daemon, bgp-daemon, br-int, "172.16.1.1/24",
> "00:00:02:01:02:03")
> +
> +ADD_NAMESPACES(ext-foo)
> +ADD_VETH(ext-foo, ext-foo, br-ext, "172.16.1.100/24", "00:10:10:01:02:13", \
> + "172.16.1.1")
> +
> +# Flip the interface down/up to get proper IPv6 LLA
> +NS_EXEC([bgp-daemon], [ip link set down bgp-daemon])
> +NS_EXEC([bgp-daemon], [ip link set up bgp-daemon])
> +NS_EXEC([ext-foo], [ip link set down ext-foo])
> +NS_EXEC([ext-foo], [ip link set up ext-foo])
> +
> +# Wait until IPv6 LLA loses the "tentative" flag otherwise it can't be bound
> to.
> +OVS_WAIT_UNTIL([NS_EXEC([bgp-daemon], [ip a show dev bgp-daemon | grep
> "fe80::" | grep -v tentative])])
> +OVS_WAIT_UNTIL([NS_EXEC([ext-foo], [ip a show dev ext-foo | grep "fe80::" |
> grep -v tentative])])
> +
> +# Verify that BGP control plane traffic is delivered to the "bgp-daemon"
> +# interface on both IPv4 and IPv6 LLA addresses
> +NETNS_DAEMONIZE([bgp-daemon], [nc -l -k 172.16.1.1 179], [bgp_v4.pid])
> +NS_CHECK_EXEC([ext-foo], [echo "BGP IPv4 server traffic" | nc --send-only
> 172.16.1.1 179])
> +
> +NETNS_DAEMONIZE([bgp-daemon], [nc -l -6 -k fe80::200:2ff:fe01:203%bgp-daemon
> 179], [bgp_v6.pid])
> +NS_CHECK_EXEC([ext-foo], [echo "BGP IPv6 server traffic" | nc --send-only -6
> fe80::200:2ff:fe01:203%ext-foo 179])
> +
> +# Perform same set of checks as above for BFD daemon.
> +# We need to manually check that the message arrived on the receiving end as
> Ncat will
> +# produce false positive results over UDP due to lack of ICMP port
> unreachable messages
> +# from LRP's IP.
> +NETNS_DAEMONIZE([bgp-daemon], [nc -l -u 172.16.1.1 3784 >
> bgp-daemon_bfd_v4.out], [bfd_v4.pid])
> +NS_CHECK_EXEC([ext-foo], [echo "from ext-foo: BFD IPv4 server traffic" | nc
> -u 172.16.1.1 3784])
> +AT_CHECK([cat bgp-daemon_bfd_v4.out], [0], [dnl
> +from ext-foo: BFD IPv4 server traffic
> +])
> +
> +NETNS_DAEMONIZE([bgp-daemon], [nc -l -6 -u fe80::200:2ff:fe01:203%bgp-daemon
> 3784 > bgp-daemon_bfd_v6.out], [bfd_v6.pid])
> +NS_CHECK_EXEC([ext-foo], [echo "from ext-foo: BFD IPv6 server traffic" | nc
> -u -6 fe80::200:2ff:fe01:203%ext-foo 3784])
> +AT_CHECK([cat bgp-daemon_bfd_v6.out], [0], [dnl
> +from ext-foo: BFD IPv6 server traffic
> +])
> +
> +# Verify connection in other direction. i.e when BGP daemon running on
> "bgp-daemon" port
> +# makes a client connection to its peer
> +NETNS_DAEMONIZE([ext-foo], [nc -l -k 172.16.1.100 179], [reply_bgp_v4.pid])
> +NS_CHECK_EXEC([bgp-daemon], [echo "BGP IPv4 client traffic" | nc --send-only
> 172.16.1.100 179])
> +
> +NETNS_DAEMONIZE([ext-foo], [nc -l -6 -k fe80::210:10ff:fe01:213%ext-foo
> 179], [reply_bgp_v6.pid])
> +NS_CHECK_EXEC([bgp-daemon], [echo "BGP IPv6 client traffic" | nc --send-only
> -6 fe80::210:10ff:fe01:213%bgp-daemon 179])
> +
> +# Perform same checks in other direction for BFD daemon
> +NETNS_DAEMONIZE([ext-foo], [nc -l -u 172.16.1.100 3784 >
> ext-foo_bfd_v4.out], [reply_bfd_v4.pid])
> +NS_CHECK_EXEC([bgp-daemon], [echo "from bgp-daemon: BFD IPv4 client traffic"
> | nc -u 172.16.1.100 3784])
> +AT_CHECK([cat ext-foo_bfd_v4.out], [0], [dnl
> +from bgp-daemon: BFD IPv4 client traffic
> +])
> +
> +NETNS_DAEMONIZE([ext-foo], [nc -l -6 -u fe80::210:10ff:fe01:213%ext-foo 3784
> > ext-foo_bfd_v6.out], [reply_bfd_v6.pid])
> +NS_CHECK_EXEC([bgp-daemon], [echo "from bgp-daemon: BFD IPv6 client traffic"
> | nc -u -6 fe80::210:10ff:fe01:213%bgp-daemon 3784])
> +AT_CHECK([cat ext-foo_bfd_v6.out], [0], [dnl
> +from bgp-daemon: BFD IPv6 client traffic
> +])
> +
> +# Verify that hosts on the internal network can reach external networks
> +NETNS_DAEMONIZE([ext-foo], [nc -l -k 172.16.1.100 2222], [nc_external.pid])
> +NS_CHECK_EXEC([bar1], [echo "TCP test" | nc -w 1 --send-only 172.16.1.100
> 2222])
> +
> +OVS_APP_EXIT_AND_WAIT([ovn-controller])
> +
> +as ovn-sb
> +OVS_APP_EXIT_AND_WAIT([ovsdb-server])
> +
> +as ovn-nb
> +OVS_APP_EXIT_AND_WAIT([ovsdb-server])
> +
> +as northd
> +OVS_APP_EXIT_AND_WAIT([ovn-northd])
> +
> +as
> +OVS_TRAFFIC_VSWITCHD_STOP(["/.*error receiving.*/d
> +/.*terminating with signal 15.*/d"])
> +AT_CLEANUP
> +])
> +
> OVN_FOR_EACH_NORTHD([
> AT_SETUP([NXT_CT_FLUSH_ZONE count])
> ovn_start --use-tcp-to-sb
> --
> 2.47.1
>
>
> _______________________________________________
> dev mailing list
> [email protected]
> https://mail.openvswitch.org/mailman/listinfo/ovs-dev
_______________________________________________
dev mailing list
[email protected]
https://mail.openvswitch.org/mailman/listinfo/ovs-dev