On Thu, Nov 20, 2025 at 9:42 AM Dumitru Ceara <[email protected]> wrote:
> Otherwise potential sanitizer reported errors might go unnoticed. > > Reported-at: > https://mail.openvswitch.org/pipermail/ovs-dev/2025-November/427811.html > Reported-by: Lucas Vargas Dias <[email protected]> > Signed-off-by: Dumitru Ceara <[email protected]> > (cherry picked from commit d1f4150bbe88713866f56603a260daae6ffa92aa) > --- > tests/ovn-macros.at | 19 + > tests/ovn-northd.at | 159 ++++++- > tests/ovn.at | 9 +- > tests/system-common-macros.at | 9 +- > tests/system-ovn-kmod.at | 72 +-- > tests/system-ovn.at | 871 ++++------------------------------ > 6 files changed, 265 insertions(+), 874 deletions(-) > > diff --git a/tests/ovn-macros.at b/tests/ovn-macros.at > index 0aa0b654e0..0ae7fcf87e 100644 > --- a/tests/ovn-macros.at > +++ b/tests/ovn-macros.at > @@ -1,3 +1,22 @@ > +# OVN_CLEANUP_NORTHD > +# > +# Gracefully terminate all central OVN daemons: NB, SB and ovn-northd. > +m4_define([OVN_CLEANUP_NORTHD],[ > + as ovn-sb > + OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > + > + as ovn-nb > + OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > + > + as northd > + OVS_APP_EXIT_AND_WAIT([ovn-northd]) > + > + if test -d northd-backup; then > + as northd-backup > + OVS_APP_EXIT_AND_WAIT([ovn-northd]) > + fi > +]) > + > # OVN_CLEANUP_VSWITCH(sim) > # > # Gracefully terminate vswitch daemons in the > diff --git a/tests/ovn-northd.at b/tests/ovn-northd.at > index 00066a7760..c7d5442d52 100644 > --- a/tests/ovn-northd.at > +++ b/tests/ovn-northd.at > @@ -152,6 +152,7 @@ check_row_count HA_Chassis 0 > check_row_count Gateway_Chassis 0 > check_row_count Ha_Chassis_Group 0 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -167,6 +168,7 @@ check ovn-sbctl chassis-add hv1 geneve 127.0.0.1 > check ovn-sbctl lsp-bind S1-vm1 hv1 > wait_row_count nb:Logical_Switch_Port 1 name=S1-vm1 'up=true' > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -181,6 +183,7 @@ check ovn-nbctl ls-add S1 > check ovn-nbctl --wait=sb lsp-add-router-port S1 S1-R1 R1-S1 > AT_CHECK([test x`ovn-nbctl lsp-get-up S1-R1` = xup]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -199,6 +202,7 @@ check ovn-nbctl --wait=sb lsp-add-router-port S1 S1-R1 > R1-S1 > check ovn-sbctl lsp-bind S1-R1 gw1 > AT_CHECK([test x`ovn-nbctl lsp-get-up S1-R1` = xup]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -216,6 +220,7 @@ check ovn-nbctl ls-add S1 > check ovn-nbctl --wait=sb lsp-add-router-port S1 S1-R1 R1-S1 > AT_CHECK([test x`ovn-nbctl lsp-get-up S1-R1` = xup]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -259,6 +264,7 @@ check ovn-nbctl --wait=sb sync > > wait_row_count nb:Logical_Router_Port 0 name=lrp1 > status:hosting-chassis=ch1 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -271,6 +277,7 @@ check ovn-nbctl lrp-add ro lrp0 00:00:00:00:00:01 > 192.168.1.1/24 > check ovn-nbctl --wait=sb set logical_router_port lrp0 > external_ids=test=123 > check_column "test=123" sb:Port_Binding external_ids logical_port=lrp0 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -380,6 +387,7 @@ AT_CHECK_UNQUOTED([ovn-sbctl get Port_Binding ${uuid} > options:ipv6_ra_prefixes], > [1], [], [ovn-sbctl: no key "ipv6_ra_prefixes" in Port_Binding record > "${uuid}" column options > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -414,13 +422,7 @@ check ovn-nbctl --wait=sb lsp-add sw p3 > # northd created with default unixctl path successfully created > port_binding entry > check_row_count Port_Binding 1 logical_port=p3 > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > - > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -756,13 +758,7 @@ wait_row_count HA_Chassis_Group 0 > wait_row_count Port_Binding 0 logical_port=sw0-pext2 'chassis!=[[]]' > check_row_count HA_Chassis 0 > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > - > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -840,6 +836,7 @@ Status: standby > check ovn-nbctl --wait=sb sync > check_row_count Datapath_Binding 1 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -867,6 +864,7 @@ check_row_count Datapath_Binding 1 > ovn_start_northd > wait_row_count Datapath_Binding 2 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -903,6 +901,7 @@ wait_row_count Datapath_Binding 2 > dp2=$(fetch_column Datapath_Binding _uuid external_ids:name=sw1) > wait_column "$dp1 $dp2" Logical_DP_Group datapaths > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -937,6 +936,7 @@ wait_row_count Datapath_Binding 2 > dp2=$(fetch_column Datapath_Binding _uuid external_ids:name=sw1) > wait_column "$dp1 $dp2" Logical_DP_Group datapaths > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -959,6 +959,7 @@ wait_row_count Port_Binding 1 logical_port=cr-R1-S1 > options:redirect-type=bridge > > check ovn-nbctl lrp-set-redirect-type R1-S1 overlay > wait_row_count Port_Binding 1 logical_port=cr-R1-S1 > options:redirect-type=overlay > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -1040,6 +1041,7 @@ echo "IPv6: stateless with match" > check ovn-nbctl --wait=sb --match="udp" --stateless lr-nat-add R1 > dnat_and_snat fd01::1 fd11::2 > check_flow_match_sets 2 0 0 0 0 1 1 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -1089,6 +1091,7 @@ AT_CHECK([grep 'ct_[s]dnat.*172\.16\.1\.2.*3000' > sbflows3], [1]) > > check ovn-nbctl lr-nat-del R1 dnat_and_snat 172.16.1.1 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -1332,12 +1335,13 @@ AT_CHECK([grep -e "lr_out_snat" crflows6 | > ovn_strip_lflows], [0], [dnl > table=??(lr_out_snat ), priority=35 , match=(ip && ip4.src == > 50.0.0.11 && ip4.dst == $disallowed_range), action=(next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > OVN_FOR_EACH_NORTHD_NO_HV([ > AT_SETUP([check Load balancer health check and Service Monitor sync]) > -ovn_start ovn-northd > +ovn_start > check ovn-nbctl lb-add lb1 10.0.0.10:80 10.0.0.3:80,20.0.0.3:80 > > check ovn-nbctl --wait=sb set load_balancer . > ip_port_mappings:10.0.0.3=sw0-p1 > @@ -1596,6 +1600,7 @@ OVS_WAIT_FOR_OUTPUT( > table=??(ls_in_lb ), priority=120 , match=(ct.new && > ip4.dst == 10.0.0.10 && tcp.dst == 80), action=(reg0 = 0; reject { outport > <-> inport; next(pipeline=egress,table=??);};) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -1671,6 +1676,7 @@ AT_CHECK([grep "lr_in_unsnat" sbflows | > ovn_strip_lflows], [0], [dnl > table=??(lr_in_unsnat ), priority=90 , match=(ip && ip4.dst == > 192.168.2.4), action=(ct_snat;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -1757,6 +1763,7 @@ AT_CHECK([grep "lr_in_ip_input" sbflows | grep > 'ip.\.dst == {' | grep drop | ovn > table=??(lr_in_ip_input ), priority=60 , match=(ip6.dst == > {fe80::200:ff:fe00:20}), action=(drop;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -1778,6 +1785,7 @@ AT_CHECK([ovn-sbctl lflow-list lr0 | grep > lr_in_unsnat | ovn_strip_lflows], [0], > table=??(lr_in_unsnat ), priority=110 , match=(ip4 && ip4.dst == > 192.168.2.3), action=(ct_snat;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -1806,6 +1814,7 @@ lr_uuid=\"$(ovn-nbctl get Logical_Router . _uuid)\" > echo nb_uuid="$nb_uuid" lr_uuid="$lr_uuid" > AT_CHECK([test "${nb_uuid}" = "${lr_uuid}"]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -1830,6 +1839,7 @@ AT_CHECK([ovn-nbctl --wait=sb sync], [0]) > check_column 1 Port_Binding tunnel_key logical_port=lsp1 > check_column 2 Port_Binding tunnel_key logical_port=lsp2 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -1858,6 +1868,7 @@ AT_CHECK([ovn-nbctl --wait=sb sync], [0]) > > check_row_count HA_Chassis_Group 0 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -1908,6 +1919,7 @@ lsp2 > check ovn-nbctl --wait=sb clear Port_Group pg_test ports > AT_CHECK([test 0 = $(ovn-sbctl --columns _uuid list Port_Group | grep > uuid -c)]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -1935,6 +1947,7 @@ check ovn-nbctl --wait=sb ls-del ls1 > wait_row_count Port_Group 1 > check_row_count Port_Group 1 name=${ls2_key}_pg_test > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -2163,6 +2176,7 @@ action=(eth.dst = eth.src; eth.src = > 00:00:00:00:00:02; arp.op = 2; /* ARP reply > # xreg0[[0..47]] isn't used anywhere else. > AT_CHECK([ovn-sbctl lflow-list | grep "xreg0\[[0..47\]]" | grep -vE > 'lr_in_admission|lr_in_ip_input'], [1], []) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -2276,6 +2290,7 @@ check ovn-nbctl --wait=sb sync > AT_CHECK([ovn-sbctl lflow-list | grep "ls_out_pre_lb.*priority=100" | > grep reg0 | ovn_strip_lflows], [0], [dnl > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -2293,6 +2308,7 @@ AT_CHECK([ovn-sbctl lflow-list | grep arp | grep > 10\.0\.0\.1], [1], [ignore]) > check ovn-nbctl --wait=sb set NB_Global . options:ignore_lsp_down=true > AT_CHECK([ovn-sbctl lflow-list | grep arp | grep 10\.0\.0\.1], [0], > [ignore]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -2367,6 +2383,7 @@ sw1flows3: table=??(ls_out_acl_eval ), > priority=2003 , match=(reg0[[10]] == > sw1flows3: table=??(ls_out_acl_eval ), priority=2003 , > match=(reg0[[9]] == 1 && (outport == @pg0 && ip6 && udp)), > action=(reg8[[18]] = 1; next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -2498,6 +2515,7 @@ check ovn-nbctl --wait=sb remove logical_switch $sw0 > acls $acl2 > check_meter_by_name meter_me meter_me__${acl3} > check_meter_by_name NOT meter_me__${acl1} meter_me__${acl2} > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -2603,6 +2621,7 @@ check_row_count sb:Mirror 0 > check_column "" sb:Port_Binding mirror_rules logical_port=sw0-port1 > check_column "" sb:Port_Binding mirror_rules logical_port=sw0-port2 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -2716,6 +2735,7 @@ AT_CHECK([ovn-sbctl lflow-list ls | grep -e > ls_in_acl_hint -e ls_out_acl_hint -e > ]) > > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -2763,6 +2783,7 @@ AT_CHECK( > [ovn-nbctl --wait=sb set logical-switch ls1 > other-config:requested-tnl-key=2]) > get_tunnel_keys > AT_CHECK([test $ls2 = 3]) > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -2783,6 +2804,7 @@ AT_CHECK([test 100 = $(ovn-sbctl get > datapath_binding lr0 tunnel_key)]) > AT_CHECK( > [ovn-nbctl --wait=sb set logical-router lr1 > options:requested-tnl-key=100]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -2842,6 +2864,7 @@ AT_CHECK( > get_tunnel_keys > AT_CHECK([test $lsp02 = 3 && test $ls1 = 123]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > OVN_FOR_EACH_NORTHD_NO_HV([ > @@ -2875,6 +2898,7 @@ check ovn-nbctl set NB_Global . > options:vxlan_mode=false > check_row_count nb:Logical_Switch 4097 > wait_row_count sb:Datapath_Binding 4097 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -2905,6 +2929,7 @@ wait_row_count sb:Datapath_Binding 4095 > > OVS_WAIT_UNTIL([grep "all datapath tunnel ids exhausted" > northd/ovn-northd.log]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -2936,6 +2961,7 @@ wait_row_count sb:Port_Binding 2048 > > OVS_WAIT_UNTIL([grep "all port tunnel ids exhausted" > northd/ovn-northd.log]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -3013,6 +3039,7 @@ AT_CHECK_UNQUOTED([ovn-sbctl --bare --columns > _uuid,datapaths find Logical_DP_Gr > $(cat sw_sb_uuids | sort) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -3280,6 +3307,7 @@ AT_CHECK_UNQUOTED([ovn-sbctl --bare --columns > _uuid,datapaths find Logical_DP_Gr > | grep -A1 $lbg0_dp_group | tail -1], [0], [dnl > $sw1_sb_uuid > ]) > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -3352,6 +3380,7 @@ AT_CHECK([ovn-sbctl lflow-list sw0 | grep > ls_in_hairpin | ovn_strip_lflows], [0] > table=??(ls_in_hairpin ), priority=1 , match=((reg0[[6]] == 1 > || reg0[[12]] == 1)), action=(eth.dst <-> eth.src; outport = inport; > flags.loopback = 1; output;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -3482,6 +3511,7 @@ sed 's/reg8\[[0..15\]] == [[0-9]]*/reg8\[[0..15\]] > == <cleared>/' | ovn_strip_lf > table=??(lr_in_policy_ecmp ), priority=150 , match=(reg8[[0..15]] == > <cleared>), action=(next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -3615,6 +3645,7 @@ ct_lb_mark { > }; > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -3751,6 +3782,7 @@ ct_lb_mark { > }; > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -3806,6 +3838,7 @@ AT_CHECK_UNQUOTED([ovn_trace --ct new --ct new > --minimal ls "${flow}"], [0], [dn > output("lsp2"); > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -3952,6 +3985,7 @@ check as northd ovn-appctl -t ovn-northd > inc-engine/clear-stats > bfd_route_policy_uuid=$(fetch_column nb:bfd _uuid logical_port=r0-sw9) > AT_CHECK([ovn-nbctl list logical_router_policy | sed s/,//g | grep -q > "$bfd_route_policy_uuid"]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -4130,6 +4164,7 @@ check ovn-nbctl --wait=hv ls-copp-add copp0 sw2 > ls2_copp_uuid=$(ovn-nbctl get Logical_Switch sw2 copp) > AT_CHECK([test "$ls2_copp_uuid" = "$copp_uuid"]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -4148,6 +4183,7 @@ check ovn-nbctl --wait=sb sync > > AT_CHECK([grep -qE 'duplicate logical port p1' northd/ovn-northd.log], > [0]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -4166,6 +4202,7 @@ check ovn-nbctl --wait=sb sync > > AT_CHECK([grep -qE 'duplicate logical router port p1' > northd/ovn-northd.log], [0]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -4181,6 +4218,7 @@ check ovn-nbctl --wait=sb sync > > AT_CHECK([grep -qE 'duplicate logical.*port p1' northd/ovn-northd.log], > [0]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -4455,6 +4493,7 @@ AT_CHECK([grep "lr_out_post_undnat" lr0flows | > ovn_strip_lflows], [0], [dnl > table=??(lr_out_post_undnat ), priority=50 , match=(ip && ct.new), > action=(ct_commit { } ; next; ) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -4497,6 +4536,7 @@ check ovn-nbctl clear logical_switch_port sw0-p1 > ha_chassis_group -- set logical > wait_row_count ha_chassis_group 0 > check_column "" Port_Binding chassis logical_port=sw0-p1 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -4559,6 +4599,7 @@ wait_row_count FDB 0 > > ovn-sbctl list FDB > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -4723,6 +4764,7 @@ AT_CHECK([ovn-sbctl dump-flows sw0 | grep "ls_in_lb > " | ovn_strip_lflows ], [0], > table=??(ls_in_lb ), priority=110 , match=(ct.trk && !ct.rpl > && reg0[[19]] == 1 && ip6), action=(xxreg1 = ct_ip6_dst(); reg2[[0..15]] = > ct_tp_dst(); next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -4816,6 +4858,7 @@ AT_CHECK([grep "ls_out_stateful" sw0flows | > ovn_strip_lflows], [0], [dnl > table=??(ls_out_stateful ), priority=100 , match=(reg0[[1]] == 1 && > reg0[[13]] == 0), action=(ct_commit { ct_mark.blocked = 0; }; next;) > table=??(ls_out_stateful ), priority=100 , match=(reg0[[1]] == 1 && > reg0[[13]] == 1), action=(ct_commit { ct_mark.blocked = 0; > ct_mark.obs_stage = reg8[[19..20]]; ct_mark.obs_collector_id = > reg8[[8..15]]; ct_label.obs_point_id = reg9; }; next;) > ]) > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -4861,6 +4904,7 @@ AT_CHECK_UNQUOTED([ovn_trace --ct new --ct new --ct > new ls "$flow" | grep -e ls_ > ct_commit { ct_mark.blocked = 0; ct_mark.obs_stage = reg8[[19..20]]; > ct_mark.obs_collector_id = reg8[[8..15]]; ct_label.obs_point_id = reg9; }; > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -4938,6 +4982,7 @@ AT_CHECK([grep -c "ct.inv" sw0flows], [0], [dnl > 6 > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -4991,7 +5036,7 @@ cp $PKIDIR/$key $key > cp $PKIDIR/$cert $cert > check ovn-nbctl --wait=sb sync > > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -5025,6 +5070,7 @@ check ovn-nbctl --wait=sb sync > > AT_CHECK([ovn_trace --minimal 'inport == "sw1-port1" && eth.src == > 50:54:00:00:00:03 && eth.dst == 00:00:00:00:ff:02 && ip4.dst == 42.42.42.42 > && ip4.src == 11.0.0.2 && ip.ttl == 64' | grep "output(\"sw0-port1\")"], > [1], [ignore]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -5058,6 +5104,7 @@ check ovn-nbctl --wait=sb sync > > AT_CHECK([ovn_trace --minimal 'inport == "sw1-port1" && eth.src == > 50:54:00:00:00:03 && eth.dst == 00:00:00:00:ff:02 && ip6.dst == fd42::42 && > ip6.src == fd11::2 && ip.ttl == 64' | grep "output(\"sw0-port1\")"], [1], > [ignore]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -5105,6 +5152,7 @@ AT_CHECK([grep -w "ls_in_dhcp_options" sw0flows | > ovn_strip_lflows], [0], [dnl > table=??(ls_in_dhcp_options ), priority=100 , match=(inport == > "sw0-port1" && eth.src == 50:54:00:00:00:01 && (ip4.src == {10.0.0.2, > 0.0.0.0} && ip4.dst == {10.0.0.1, 255.255.255.255}) && udp.src == 68 && > udp.dst == 67), action=(reg0[[3]] = put_dhcp_opts(offerip = 10.0.0.2, > hostname = "bar", lease_time = 3600, netmask = 255.255.255.0, router = > 10.0.0.1, server_id = 10.0.0.1); next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -5352,6 +5400,7 @@ check ovn-nbctl --wait=sb clear logical_router_port > ro2-sw ha_chassis_group > > check_lflows 0 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -5559,6 +5608,7 @@ AT_CHECK([grep "ls_in_l2_lkup" ls1_lflows | > ovn_strip_lflows], [0], [dnl > AT_CHECK([grep "ls_in_l2_lkup" ls1_lflows | grep "192.168.4.100" | grep > -v clone | grep "_MC_flood" -c], [1], [0 > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -6384,6 +6434,7 @@ AT_CHECK([ovn-sbctl dump-flows lr0 | grep > "lr_in_dnat" | ovn_strip_lflows], [0], > table=??(lr_in_dnat ), priority=70 , match=(ct.rel && !ct.est > && !ct.new && !ct.rpl && ct_mark.skip_snat == 1), > action=(flags.skip_snat_for_lb = 1; ct_commit_nat;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -6401,6 +6452,7 @@ AT_CHECK([ovn-sbctl create Load_Balancer name=lb1 > ls_datapath_group="$dps" exter > check ovn-nbctl --wait=sb sync > check_row_count Load_Balancer 1 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -6428,6 +6480,7 @@ AT_CHECK([ovn-sbctl --columns=tags list logical_flow > | grep lsp0 -c], [0], [dnl > 3 > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -6729,6 +6782,7 @@ check ovn-nbctl --wait=sb sync > ovn-sbctl dump-flows lr0 > lr0flows > AT_CHECK([grep -E "lr_out_post_snat.*ct_commit_nat" lr0flows], [1]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ])]) > > @@ -6832,6 +6886,7 @@ AT_CHECK([grep -e "lr_in_ip_routing.*2.0.0.0" > lr0flows | ovn_strip_lflows], [0], > table=??(lr_in_ip_routing ), priority=73 , match=(reg7 == 0 && > ip4.dst == 2.0.0.0/24), action=(ip.ttl--; reg8[[0..15]] = 0; reg0 = > ip4.dst; reg1 = 192.168.0.1; eth.src = 00:00:20:20:12:13; outport = > "lr0-public"; flags.loopback = 1; next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -6908,6 +6963,7 @@ AT_CHECK([grep lr_in_gw_redirect lrflows | grep > cr-DR | ovn_strip_lflows], [0], > table=??(lr_in_gw_redirect ), priority=50 , match=(outport == > "DR-S3"), action=(outport = "cr-DR-S3"; next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -7000,6 +7056,7 @@ AT_CHECK([grep lr_in_gw_redirect lrflows | grep lrp1 > | ovn_strip_lflows], [0], [ > > wait_row_count Port_Binding 1 logical_port=cr-lrp1 > options:always-redirect="true" > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -7046,13 +7103,14 @@ check ovn-nbctl --wait=sb set logical_switch_port > S1-vm2 \ > > wait_row_count Port_binding 1 logical-port=S1-vm2 > requested_chassis=$ch2_uuid > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > > OVN_FOR_EACH_NORTHD_NO_HV([ > AT_SETUP([check options: force_fdb_lookup for LSP]) > -ovn_start NORTHD_TYPE > +ovn_start > check ovn-nbctl ls-add S1 > check ovn-nbctl --wait=sb lsp-add S1 S1-vm1 > check ovn-nbctl --wait=sb lsp-add S1 S1-localnet > @@ -7084,13 +7142,14 @@ AT_CHECK([grep -e "ls_in_.*_fdb.*S1-vm1" S1flows | > ovn_strip_lflows], [0], [dnl > #Verify the flows for a non-default port type (localnet port) > AT_CHECK([grep -e "ls_in_.*_fdb.*S1-localnet" S1flows], [1], []) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > > OVN_FOR_EACH_NORTHD_NO_HV([ > AT_SETUP([check options:pkt_clone_type for LSP]) > -ovn_start NORTHD_TYPE > +ovn_start > check ovn-nbctl ls-add S1 > check ovn-nbctl --wait=sb lsp-add S1 S1-vm1 > check ovn-nbctl --wait=sb lsp-add S1 S1-vm2 > @@ -7124,6 +7183,7 @@ AT_CHECK([grep -e "ls_in_l2_lkup.*S1-vm1" S1flows | > ovn_strip_lflows], [0], [dnl > table=??(ls_in_l2_lkup ), priority=50 , match=(eth.dst == > 50:54:00:00:00:01), action=(outport = "S1-vm1"; output;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -7146,6 +7206,7 @@ AT_CHECK([ovn-sbctl --id=@dp create Datapath_Binding > external_ids:logical-switch > # northd should delete one of the datapaths in the end > wait_row_count Datapath_Binding 1 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -7186,6 +7247,7 @@ AT_CHECK_UNQUOTED([ovn_trace --minimal "${flow}" > --lb-dst 42.42.42.42:4242], [0] > ct_dnat /* assuming no un-dnat entry, so no change */ /* default (use > --ct to customize) */; > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -7253,6 +7315,7 @@ AT_CHECK([grep -e "(lr_in_ip_routing ).*outport" > lr0flows | ovn_strip_lflows], > table=??(lr_in_ip_routing ), priority=97 , match=(reg7 == 2 && > ip4.dst == 1.1.1.1/32), action=(ip.ttl--; reg8[[0..15]] = 0; reg0 = > 192.168.0.20; reg1 = 192.168.0.1; eth.src = 00:00:00:00:00:01; outport = > "lrp0"; flags.loopback = 1; next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -7284,6 +7347,7 @@ check ovn-nbctl --wait=sb lsp-set-options S1-R1 > router-port=R1-S1 nat-addresses= > > AT_CHECK([ovn-sbctl get Port_Binding S1-R1 nat_addresses |grep -q > 172.16.1.10], [1]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -7314,6 +7378,7 @@ check ovn-nbctl --wait=sb set Logical_Switch S1 \ > > AT_CHECK([ovn-sbctl lflow-list S1 | grep ls_in_l2_lkup | grep -q > 'match=(eth.mcast && (arp.op == 1 || nd_ns)), action=(outport = > "_MC_flood_l2"; output;)'], [1]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -7565,6 +7630,7 @@ check ovn-nbctl --wait=sb sync > check_log_flows_count 0 out > check_log_flows_count 0 in > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -7609,6 +7675,7 @@ AT_CHECK([grep -e 'lr_in_ip_routing ' lrflows | > grep -e 'igmp' -e 'mld' | ovn_ > table=??(lr_in_ip_routing ), priority=10550, match=(eth.src == > 00:00:00:00:00:02 && igmp), action=(drop;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -7792,6 +7859,7 @@ AT_CHECK([grep -e "ls_in_stateful" lsflows | > ovn_strip_lflows], [0], [dnl > table=??(ls_in_stateful ), priority=100 , match=(reg0[[1]] == 1 && > reg0[[13]] == 1), action=(ct_commit { ct_mark.blocked = 0; > ct_mark.obs_stage = reg8[[19..20]]; ct_mark.obs_collector_id = > reg8[[8..15]]; ct_label.obs_point_id = reg9; }; next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -7984,6 +8052,7 @@ check ovn-nbctl --wait=sb lr-nat-del DR dnat_and_snat > AT_CHECK([ovn-sbctl dump-flows DR | grep -e lr_in_unsnat -e lr_out_snat > -e lr_in_dnat -e lr_out_undnat | grep ct_snat| wc -l], [0], [0 > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -8031,6 +8100,7 @@ check ovn-nbctl lrp-del lr-lrp -- lr-del lr -- > lr-add lr -- lrp-add lr lr-lrp 00 > wait_row_count sb:Static_MAC_Binding 1 > check ovn-nbctl --wait=sb sync > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -8058,6 +8128,7 @@ AT_CHECK([cat lrflows | grep -e > lr_in_lookup_neighbor -e lr_in_learn_neighbor | > table=??(lr_in_lookup_neighbor), priority=100 , match=(nd_ns), > action=(reg9[[2]] = lookup_nd(inport, ip6.src, nd.sll); next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -8748,6 +8819,7 @@ AT_CHECK_UNQUOTED([ovn_trace --ct new --ct new > --minimal ls "${flow}"], [0], [dn > ct_next(ct_state=new|trk); > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -8792,6 +8864,7 @@ AT_CHECK([as northd ovn-appctl -t ovn-northd > parallel-build/set-n-threads 1 2], > ovn-appctl: ovn-northd: server returned an error > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -8860,6 +8933,7 @@ check ovn-nbctl --wait=sb sync > ovn-sbctl dump-flows | DUMP_FLOWS_SORTED > flows3 > AT_CHECK([diff flows1 flows3]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -9067,6 +9141,7 @@ ovn_strip_lflows ], [0], [dnl > table=??(ls_out_check_port_sec), priority=100 , match=(eth.mcast), > action=(reg0[[15]] = 0; next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -9101,6 +9176,7 @@ AT_CHECK([ovn-sbctl dump-flows ls0 | grep -e > 'ls_in_\(put\|lookup\)_fdb' | ovn_s > table=??(ls_in_put_fdb ), priority=0 , match=(1), action=(next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -9189,6 +9265,7 @@ AT_CHECK([grep "ls_in_lb " S1flows | > ovn_strip_lflows], [0], [dnl > > check_column "" sb:load_balancer datapaths name=lb0 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -9224,6 +9301,7 @@ AT_CHECK([grep "lr_in_arp_resolve" R1flows | grep > priority=90 | ovn_strip_lflows > table=??(lr_in_arp_resolve ), priority=90 , match=(outport == > "R1-PUB" && ip6.src == 1000::3 && is_chassis_resident("S0-P0")), > action=(get_nd(outport, xxreg0); next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -9408,12 +9486,13 @@ AT_CHECK([grep "lr_in_dnat " R1flows_2lbs | > ovn_strip_lflows], [0], [dnl > ]) > > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > OVN_FOR_EACH_NORTHD_NO_HV([ > AT_SETUP([check options:disable_arp_nd_rsp for LSP]) > -ovn_start NORTHD_TYPE > +ovn_start > check ovn-nbctl ls-add S1 > check ovn-nbctl --wait=sb lsp-add S1 S1-vm1 > check ovn-nbctl --wait=sb lsp-set-addresses S1-vm1 "50:54:00:00:00:010 > 192.168.0.10 fd00::10" > @@ -9439,6 +9518,7 @@ AT_CHECK([grep -e "ls_in_arp_rsp" S1flows | > ovn_strip_lflows], [0], [dnl > table=??(ls_in_arp_rsp ), priority=0 , match=(1), action=(next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -9543,6 +9623,7 @@ check ovn-nbctl --wait=sb sync > AT_CHECK([as northd ovn-appctl -t ovn-northd inc-engine/show-stats > sync_to_sb_addr_set recompute], [0], [0 > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -9905,6 +9986,7 @@ dnl Expect both ACLs on sw1 and no ACLs on sw2 > check_acl_lflows 1 1 0 0 > CHECK_NO_CHANGE_AFTER_RECOMPUTE > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -10033,6 +10115,7 @@ AT_CHECK([ovn-sbctl dump-flows | grep "ls_in_acl" > | grep "match=(1)" | ovn_stri > table=??(ls_in_acl_sample ), priority=0 , match=(1), action=(next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -10068,6 +10151,7 @@ check ovn-nbctl destroy Chassis_Template_Var hv2 > check ovn-nbctl --wait=sb sync > check_row_count sb:Chassis_Template_Var 0 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -10096,6 +10180,7 @@ AT_CHECK([as northd ovn-appctl -t ovn-northd > debug/chassis-features-list], [0], > mac_binding_timestamp: true > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -10118,6 +10203,7 @@ AT_CHECK([fetch_column sb:Port_Binding options > logical_port=public |grep -q 'qos > check ovn-nbctl --wait=sb set Logical_Switch_Port public > options:qos_min_rate=200000 options:network_name=phys > AT_CHECK([fetch_column sb:Port_Binding options logical_port=public |grep > -q 'qos_physical_network=phys']) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -10153,6 +10239,7 @@ AT_CHECK([ovn-sbctl lflow-list ls | grep qos | > ovn_strip_lflows], [0], [dnl > table=??(ls_out_qos ), priority=103 , match=(ip4), > action=(ip.dscp = 17; pkt.mark = 18; next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -10279,6 +10366,7 @@ acl_test from-lport "" pg ls_in_acl_eval > ls_in_acl_action > acl_test from-lport "--apply-after-lb" pg ls_in_acl_after_lb_eval > ls_in_acl_after_lb_action > acl_test to-lport "" pg ls_out_acl_eval ls_out_acl_action > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -10325,6 +10413,7 @@ acl_test from-lport "" pg ls_in_acl_eval > acl_test from-lport "--apply-after-lb" pg ls_in_acl_after_lb_eval > acl_test to-lport "" pg ls_out_acl_eval > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -10385,6 +10474,7 @@ AT_CHECK_UNQUOTED([ovn_trace --ct new --ct new > --ct new s1 "$flow" | grep -e ls_ > ct_commit { ct_mark.blocked = 0; }; > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -10444,6 +10534,7 @@ AT_CHECK([ovn-sbctl lflow-list sw | grep > ls_out_pre_lb | grep priority=110 | gre > table=??(ls_out_pre_lb ), priority=110 , match=(ip && outport == > "sw-ln"), action=(ct_clear; next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -10467,6 +10558,7 @@ check ovn-nbctl --wait=sb lsp-set-type p1 external > sb_lb_recomp=$(as northd ovn-appctl -t ovn-northd inc-engine/show-stats > sync_to_sb_lb recompute) > AT_CHECK([test x$sb_lb_recomp != x0]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -10622,6 +10714,7 @@ check ovn-nbctl --wait=hv lsp-del lsp0-1 > check_recompute_counter 0 0 > CHECK_NO_CHANGE_AFTER_RECOMPUTE > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -10825,6 +10918,7 @@ dnl Only triggers recompute of the sync_meters and > lflow nodes. > check_recompute_counter 0 2 2 > CHECK_NO_CHANGE_AFTER_RECOMPUTE(1) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -10876,6 +10970,7 @@ AT_CHECK([grep "lr_in_gw_redirect" R1flows |sed > s'/table=../table=??/' |sort], [ > table=??(lr_in_gw_redirect ), priority=50 , match=(outport == > "R1-PUB"), action=(outport = "cr-R1-PUB"; next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -10943,6 +11038,7 @@ check_column $remote_chassis_uuid Port_Binding > chassis logical_port=sw0-r1 > check ovn-nbctl --wait=hv lsp-set-type sw0-r1 router > check_column '' Port_Binding chassis logical_port=sw0-r1 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -11585,6 +11681,7 @@ check ovn-nbctl --wait=sb lb-add lb4 > 10.0.0.40:4040 10.0.40.40:4050 \ > check_engine_stats northd recompute nocompute > CHECK_NO_CHANGE_AFTER_RECOMPUTE > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -11638,6 +11735,7 @@ AT_CHECK([as northd ovn-appctl -t ovn-northd > status], [0], [dnl > Status: active > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -11763,6 +11861,7 @@ AT_CHECK([ovn-sbctl dump-flows S1 | grep pre_acl | > ovn_strip_lflows], [0], [dnl > table=??(ls_out_pre_acl ), priority=110 , match=(nd || nd_rs || > nd_ra || mldv1 || mldv2 || (udp && udp.src == 546 && udp.dst == 547)), > action=(next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -11805,6 +11904,7 @@ check_engine_stats lflow recompute nocompute > check_engine_stats sync_to_sb_lb recompute compute > CHECK_NO_CHANGE_AFTER_RECOMPUTE > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -12026,6 +12126,7 @@ AT_CHECK([echo $dpgrp_dps | grep $sw3_uuid], [0], > [ignore]) > AT_CHECK([echo $dpgrp_dps | grep $sw4_uuid], [0], [ignore]) > AT_CHECK([echo $dpgrp_dps | grep $sw5_uuid], [0], [ignore]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -12314,12 +12415,13 @@ ovn-nbctl: constraint violation: -2 is not in > the valid range 0 to 4294967295 (i > ]) > check_row_count nb:QoS 0 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > OVN_FOR_EACH_NORTHD_NO_HV([ > AT_SETUP([check DHCP RELAY]) > -ovn_start NORTHD_TYPE > +ovn_start > > check ovn-nbctl ls-add ls0 > check ovn-nbctl lsp-add ls0 ls0-port1 > @@ -12383,6 +12485,7 @@ AT_CAPTURE_FILE([lflows]) > AT_CHECK([grep -e "DHCP_RELAY_" lflows | sed 's/table=../table=??/'], > [0], [dnl > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -12398,6 +12501,7 @@ check ovn-nbctl --wait=hv sync > flow_desc=$(fetch_column Logical_flow flow_desc match='"outport == > \"none\""') > AT_CHECK([test "$flow_desc" != ""]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -12571,6 +12675,7 @@ check_engine_stats fdb_aging recompute nocompute > check_engine_stats northd recompute nocompute > check_engine_stats lflow recompute nocompute > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > > OVN_FOR_EACH_NORTHD_NO_HV([ > @@ -12589,6 +12694,7 @@ check_engine_stats lflow recompute nocompute > check_engine_stats global_config recompute nocompute > CHECK_NO_CHANGE_AFTER_RECOMPUTE > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -12613,6 +12719,7 @@ AT_CHECK([ovn-sbctl lflow-list | grep > ls_in_l2_unknown.*sample | ovn_strip_lflow > table=??(ls_in_l2_unknown ), priority=50 , match=(outport == > "none"), > action=(sample(probability=65535,collector_set=123,obs_domain=42,obs_point=$cookie); > /* drop */) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -12832,6 +12939,7 @@ AT_CHECK_UNQUOTED([ovn_trace --ct est --ct est ls > "$flow" | TRACE_FILTER], [0], > reg9 = 0; > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -13106,6 +13214,7 @@ AT_CHECK_UNQUOTED([ovn_trace --ct est --ct est ls > "$flow" | TRACE_FILTER], [0], > reg9 = 0; > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -13166,6 +13275,7 @@ > action=(sample(probability=20000,collector_set=100,obs_domain=43,obs_point=ct_la > > action=(sample(probability=20000,collector_set=100,obs_domain=43,obs_point=ct_label.obs_point_id); > next;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -13218,6 +13328,7 @@ AT_CHECK([ovn-sbctl dump-flows lr | grep > lr_in_dnat | ovn_strip_lflows], [0], [d > table=??(lr_in_dnat ), priority=320 , match=(ip && ip4.dst == > 10.0.0.100 && (udp)), action=(flags.loopback = 1; ct_dnat(10.0.0.20);) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -13709,6 +13820,7 @@ AT_CHECK([grep -Fe "172.168.0.110" -e > "172.168.0.120" -e "10.0.0.3" -e "20.0.0.3 > table=??(ls_in_l2_lkup ), priority=80 , match=(flags[[1]] == 0 > && arp.op == 1 && arp.tpa == 172.168.0.120), action=(clone {outport = > "public-lr0"; output; }; outport = "_MC_flood_l2"; output;) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -13809,6 +13921,7 @@ check ovn-nbctl --wait=sb set logical_router_port > lr-ls options:routing-protocol > check ovn-nbctl --wait=sb set logical_router_port lr-ls > options:routing-protocols=BGP,BFD > check_no_redirect > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -13891,6 +14004,7 @@ check_uuid ovn-sbctl create RBAC_Role > name=custom-role permissions:Load_Balancer > OVS_WAIT_UNTIL([rbr_match_builtin]) > check rbr_match_custom > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > > OVN_FOR_EACH_NORTHD_NO_HV([ > @@ -13952,6 +14066,7 @@ AT_CHECK([ovn-sbctl lflow-list S2 | grep > ls_in_acl_action | grep priority=500 | > table=??(ls_in_acl_action ), priority=500 , match=(reg8[[30..31]] == > 0), action=(reg8[[30..31]] = 1; next(pipeline=ingress,table=??);) > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -13999,6 +14114,7 @@ check_row_count Port_Binding 1 logical_port=lrp0 > options:peer{not-in}lrp1 > check_row_count Port_Binding 1 logical_port=lrp1 options:peer{not-in}lrp2 > check_row_count Port_Binding 1 logical_port=lrp2 options:peer{not-in}lrp0 > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -14015,6 +14131,7 @@ check ovn-nbctl --wait=sb sync \ > > check grep -q "Bad configuration: The peer of the switch port 'ls-lrp1' > (LRP peer: 'lrp1') has its own peer configuration: 'lrp0'" > northd/ovn-northd.log > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -14128,6 +14245,7 @@ AT_CHECK([grep -E flags.network_id lrflows | > ovn_strip_lflows], [0], [dnl > table=??(lr_out_snat ), priority=110 , > match=(flags.force_snat_for_lb == 1 && flags.network_id == 9 && ip4 && > outport == "lrp-server"), action=(ct_snat(6.5.1.1);) > table=??(lr_out_snat ), priority=110 , > match=(flags.force_snat_for_lb == 1 && flags.network_id == 9 && ip6 && > outport == "lrp-server"), action=(ct_snat(ff01::b);) > ]) > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > @@ -14204,5 +14322,6 @@ AT_CHECK([ovn-sbctl lflow-list ls1 | grep > ls_in_arp_rsp | grep "eth.dst == 00:00 > AT_CHECK([ovn-sbctl lflow-list ls1 | grep ls_in_arp_rsp | grep "ip6.dst > == fd01::1" | ovn_strip_lflows], [0], [dnl > ]) > > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > diff --git a/tests/ovn.at b/tests/ovn.at > index f6905b9789..8b0f32e092 100644 > --- a/tests/ovn.at > +++ b/tests/ovn.at > @@ -9075,14 +9075,7 @@ AT_CHECK([ovn-nbctl list Logical-Switch-Port | grep > 192.10.2.127], [1]) > AT_CHECK([ovn-nbctl list Logical-Switch-Port | grep 192.10.2.128], [1]) > AT_CHECK([ovn-nbctl list Logical-Switch-Port | grep 192.10.2.180], [1]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > AT_CLEANUP > ]) > > diff --git a/tests/system-common-macros.at b/tests/system-common-macros.at > index 7de686c9ad..60a9f34453 100644 > --- a/tests/system-common-macros.at > +++ b/tests/system-common-macros.at > @@ -312,14 +312,7 @@ AT_CHECK([ovn-nbctl get logical_router_port rp-sw0 > ipv6_prefix | cut -c3-15], [0 > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/.*error receiving.*/d > diff --git a/tests/system-ovn-kmod.at b/tests/system-ovn-kmod.at > index 1454fabd70..5cf1ccd55a 100644 > --- a/tests/system-ovn-kmod.at > +++ b/tests/system-ovn-kmod.at > @@ -285,14 +285,7 @@ NS_CHECK_EXEC([foo1], [nc -z 192.168.1.100 8081]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -583,14 +576,7 @@ NS_CHECK_EXEC([foo1], [nc -z fd11::a 8081]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -725,14 +711,7 @@ check ovn-nbctl lb-del lb1 > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -882,14 +861,7 @@ done > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -1056,14 +1028,7 @@ ovn-appctl -t ovn-controller vlog/set info > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP([" > @@ -1128,14 +1093,7 @@ check cmp frag_test_client.expected > udp_frag_test_c2.recvd > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -1197,14 +1155,7 @@ check cmp frag_test_client.expected > udp_frag_test_c2.recvd > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -1316,14 +1267,7 @@ ovs-appctl revalidator/resume > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > diff --git a/tests/system-ovn.at b/tests/system-ovn.at > index 7d502ee4ab..d05837105f 100644 > --- a/tests/system-ovn.at > +++ b/tests/system-ovn.at > @@ -164,14 +164,7 @@ > icmp,orig=(src=192.168.2.2,dst=192.168.1.2,id=<cleared>,type=8,code=0),reply=(sr > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -344,14 +337,7 @@ > icmpv6,orig=(src=fd12::2,dst=fd11::2,id=<cleared>,type=128,code=0),reply=(src=fd > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -456,14 +442,7 @@ > icmp,orig=(src=192.168.1.2,dst=172.16.1.2,id=<cleared>,type=8,code=0),reply=(src > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -568,14 +547,7 @@ > icmpv6,orig=(src=fd10::2,dst=fd30::2,id=<cleared>,type=128,code=0),reply=(src=fd > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -790,14 +762,7 @@ > icmp,orig=(src=192.168.1.2,dst=172.16.1.3,id=<cleared>,type=8,code=0),reply=(src > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -1016,14 +981,7 @@ > icmpv6,orig=(src=fd11::2,dst=fd30::3,id=<cleared>,type=128,code=0),reply=(src=fd > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -1330,14 +1288,7 @@ > icmpv6,orig=(src=fd11::2,dst=fd30::3,id=<cleared>,type=128,code=0),reply=(src=fd > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -1612,14 +1563,7 @@ OVS_WAIT_UNTIL([ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d"]) > @@ -1833,14 +1777,7 @@ else > fi > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d"]) > @@ -1941,14 +1878,7 @@ > tcp,orig=(src=192.168.1.2,dst=30.0.0.2,sport=<cleared>,dport=<cleared>),reply=(s > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d"]) > @@ -2051,14 +1981,7 @@ > tcp,orig=(src=fd01::2,dst=fd03::2,sport=<cleared>,dport=<cleared>),reply=(src=fd > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d"]) > @@ -2300,14 +2223,7 @@ OVS_WAIT_UNTIL([check_est_flows], [check > established flows]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -2392,14 +2308,7 @@ done > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -2549,14 +2458,7 @@ > tcp,orig=(src=fd72::2,dst=fd30::2,sport=<cleared>,dport=<cleared>),reply=(src=fd > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -2720,14 +2622,7 @@ test "x$ct1 = x$exp_ct1" && test "x$ct2 = x$exp_ct2" > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -2893,14 +2788,7 @@ test "x$ct1 = x$exp_ct1" && test "x$ct2 = x$exp_ct2" > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -3114,14 +3002,7 @@ test "x$ct1 = x$exp_ct1" && test "x$ct2 = > x$exp_ct2" && test "x$ct3 = x$exp_ct3" > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -3257,14 +3138,7 @@ > tcp,orig=(src=172.16.1.2,dst=172.16.1.11,sport=<cleared>,dport=<cleared>),reply= > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -3400,14 +3274,7 @@ > tcp,orig=(src=fd72::2,dst=fd72::11,sport=<cleared>,dport=<cleared>),reply=(src=f > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -3583,14 +3450,7 @@ OVS_WAIT_UNTIL([ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -3746,14 +3606,7 @@ NS_CHECK_CONNECTIVITY_V6([alice1], [bar1], > [fd12::2]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -3929,14 +3782,7 @@ > icmp,orig=(src=192.168.1.3,dst=172.16.1.4,id=<cleared>,type=8,code=0),reply=(src > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -4096,14 +3942,7 @@ > icmpv6,orig=(src=fd20::1,dst=fd20::4,id=<cleared>,type=128,code=0),reply=(src=fd > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -4173,14 +4012,7 @@ OVS_WAIT_WHILE([ovs-appctl dpctl/dump-conntrack > zone=$zone_id | grep .]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -4339,14 +4171,7 @@ OVS_WAIT_UNTIL([ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -4557,14 +4382,7 @@ OVS_WAIT_UNTIL([ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -4734,14 +4552,7 @@ wait_row_count Service_Monitor 1 status=online > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -4833,14 +4644,7 @@ NS_CHECK_EXEC([lsp], [nc 88.88.88.89 8080 -z], [0], > [ignore], [ignore]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -4927,14 +4731,7 @@ NS_CHECK_EXEC([lsp], [nc 8800::0089 8080 -z], [0], > [ignore], [ignore]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -5154,14 +4951,7 @@ aef0::3 udp port 90" | uniq | wc -l) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -5385,14 +5175,7 @@ aef0::3 udp port 90" | uniq | wc -l) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -5505,14 +5288,7 @@ AT_CHECK([ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -5619,14 +5395,7 @@ NS_CHECK_EXEC([sw0-p1-lbc], [nc -z 30.0.0.10 80], > [0], [ignore], [ignore]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -5726,14 +5495,7 @@ > tcp,orig=(src=42.42.42.3,dst=66.66.66.66,sport=<clnt_s_port>,dport=666),reply=(s > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -5833,14 +5595,7 @@ > tcp,orig=(src=4242::3,dst=6666::1,sport=<clnt_s_port>,dport=666),reply=(src=4242 > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -5927,14 +5682,7 @@ NS_CHECK_EXEC([sw0-p1-f], [ping -q -c 3 -i 0.3 -w 2 > 10.0.0.5 | FORMAT_PING], \ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -6143,14 +5891,7 @@ > tcp,orig=(src=172.16.0.1,dst=10.0.0.2,sport=<cleared>,dport=<cleared>),reply=(sr > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -6375,14 +6116,7 @@ > tcp,orig=(src=fd07::1,dst=fd01::2,sport=<cleared>,dport=<cleared>),reply=(src=fd > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -6424,14 +6158,7 @@ OVS_WAIT_UNTIL([test x$(ovn-nbctl lsp-get-up > sw0-port1) = xdown]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -6512,14 +6239,7 @@ > icmp,orig=(src=192.168.1.2,dst=172.16.1.100,id=<cleared>,type=8,code=0),reply=(s > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/.*error receiving.*/d > @@ -6742,14 +6462,7 @@ OVS_WAIT_UNTIL([tc class show dev ovs-public | \ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/.*error receiving.*/d > @@ -6944,14 +6657,7 @@ check ovn-nbctl destroy bfd $uuid_v6 > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/.*error receiving.*/d > @@ -7073,14 +6779,7 @@ AT_CHECK([ovs-appctl dpctl/dump-flows | grep > ct_mark | grep -v ipv6 -c], [1], [d > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -7192,14 +6891,7 @@ NS_CHECK_EXEC([vm2], [ping -q -c 3 -i 0.3 -w 2 > 172.18.2.10 | FORMAT_PING], \ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/.*error receiving.*/d > @@ -7297,14 +6989,7 @@ NS_CHECK_EXEC([vm1], [ping -q -c 3 -i 0.3 -w 2 > 172.18.2.12 | FORMAT_PING], \ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -7507,14 +7192,7 @@ OVS_WAIT_UNTIL([test "1" = "$(grep -c > "dl_dst=33:33:33:33:33:33" ovn-controller. > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/.*error receiving.*/d > @@ -7650,14 +7328,7 @@ > icmp,orig=(src=10.0.0.3,dst=10.0.0.2,id=<cleared>,type=8,code=0),reply=(src=10.0 > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -7792,14 +7463,7 @@ > icmp,orig=(src=10.0.0.3,dst=10.0.0.2,id=<cleared>,type=8,code=0),reply=(src=10.0 > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -7893,14 +7557,7 @@ > icmp,orig=(src=10.0.0.2,dst=10.0.0.3,id=<cleared>,type=8,code=0),reply=(src=10.0 > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -7994,14 +7651,7 @@ > icmp,orig=(src=10.0.0.2,dst=10.0.0.3,id=<cleared>,type=8,code=0),reply=(src=10.0 > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -8088,14 +7738,7 @@ AT_CHECK([ip netns exec sw0p1 wget 20.0.0.3 -t 3 -T > 1], [0], [ignore], [ignore]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -8445,14 +8088,7 @@ check $PYTHON $srcdir/check_acl_log.py \ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -8574,14 +8210,7 @@ AT_CHECK([ovs-appctl dpctl/flush-conntrack]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -8636,14 +8265,7 @@ NS_CHECK_EXEC([sw0-p1.2], [ping -q -c 3 -i 0.3 -w 2 > 10.0.0.3 | FORMAT_PING], \ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -8725,14 +8347,7 @@ NS_CHECK_EXEC([ls1p1], [ping6 -q -c 3 -i 0.3 -w 2 > 1711::1 | FORMAT_PING], \ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -8834,14 +8449,7 @@ AT_CHECK([grep -qE 'Too many active mcast flows' > northd/ovn-northd.log], [1]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -8903,14 +8511,7 @@ NS_CHECK_EXEC([vif0], [ping -q -c 3 -i 0.3 -w 1 > 192.168.20.1 | FORMAT_PING], \ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -9105,14 +8706,7 @@ > udp,orig=(src=192.168.10.10,dst=192.168.20.20,sport=<cleared>,dport=<cleared>),r > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -9249,14 +8843,7 @@ OVS_WAIT_UNTIL([ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -9394,14 +8981,7 @@ OVS_WAIT_UNTIL([ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -9519,14 +9099,7 @@ OVS_WAIT_UNTIL([ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -9670,14 +9243,7 @@ AT_CHECK([ovs-appctl dpctl/flush-conntrack]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -9814,14 +9380,7 @@ AT_CHECK([ovs-appctl dpctl/flush-conntrack]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -9910,14 +9469,7 @@ NS_CHECK_EXEC([ns_ls1p1], [ping -q -c 3 -i 0.3 -w 2 > 10.89.189.1 | FORMAT_PING], > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -10052,14 +9604,7 @@ NS_CHECK_EXEC([vm1], [ping -q -c 3 -i 0.3 -w 2 > 10.0.0.2 | FORMAT_PING], \ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -10266,14 +9811,7 @@ AT_CHECK([ovs-appctl dpctl/dump-conntrack | > FORMAT_CT(30.0.0.1) | sed -e 's/zone > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -10407,14 +9945,7 @@ NS_CHECK_EXEC([ns_ext1], [ping -q -c 3 -i 0.3 -w 2 > 172.0.0.88 | FORMAT_PING], \ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -10561,14 +10092,7 @@ OVS_WAIT_UNTIL([ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -10729,14 +10253,7 @@ OVS_WAIT_UNTIL([ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -10862,14 +10379,7 @@ OVS_WAIT_UNTIL([ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -11195,14 +10705,7 @@ TMPPID=$(cat $OVS_RUNDIR/ovn-controller.pid) > check ovs-appctl -t ovn-controller exit --restart > OVS_WAIT_WHILE([kill -0 $TMPPID 2>/dev/null]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > AT_CLEANUP > ]) > @@ -11355,14 +10858,7 @@ OVS_WAIT_UNTIL([ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -11497,14 +10993,7 @@ acl_test to-lport "" pg > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -11577,14 +11066,7 @@ > tcp,orig=(src=10.0.0.2,dst=172.16.0.1,sport=<cleared>,dport=<cleared>),reply=(sr > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -11647,14 +11129,7 @@ check_row_count mac_binding 1 > mac=\"00:00:00:00:00:02\" > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -11761,14 +11236,7 @@ OVS_WAIT_FOR_OUTPUT([ovs-appctl > dpctl/dump-conntrack | FORMAT_CT(172.16.1.151) | > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -11974,14 +11442,7 @@ OVS_WAIT_UNTIL([check_est_flows 0xa], [check > established flows]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -12059,14 +11520,7 @@ AT_CHECK([ovs-ofctl dump-flows br-int | grep > 'table=OFTABLE_CHK_LB_AFFINITY, n_p > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -12149,14 +11603,7 @@ NS_CHECK_EXEC([sw1-p0], [ping -q -c 3 -i 0.3 -w 2 > 172.16.1.100 | FORMAT_PING], \ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -12259,14 +11706,7 @@ wait_row_count MAC_Binding 1 logical_port=lr1-pub > ip=172.24.4.100 > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -12351,14 +11791,7 @@ AT_CHECK([ovs-appctl dpctl/dump-conntrack | grep > -c "zone=$zone_id"], [0], [2 > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -12495,14 +11928,7 @@ NS_CHECK_EXEC([sw11], [ip addr show sw11 | grep > -oP '(?<=inet\s)\d+(\.\d+){3}'], > ]) > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/.*error receiving.*/d > @@ -12629,14 +12055,7 @@ check_dnat > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -12762,14 +12181,7 @@ check_dnat > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -13002,14 +12414,7 @@ AT_CHECK([for f in $(ls -1 nfcapd.*); do nfdump > -o json -r $f; done | grep obser > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -13129,14 +12534,7 @@ AT_CHECK([for f in $(ls -1 nfcapd.*); do nfdump > -o json -r $f; done | grep obser > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -13253,14 +12651,7 @@ AT_CHECK([for f in $(ls -1 nfcapd.*); do nfdump > -o json -r $f; done | grep obser > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -13374,14 +12765,7 @@ AT_CHECK([for f in $(ls -1 nfcapd.*); do nfdump > -o json -r $f; done | grep obser > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -13493,14 +12877,7 @@ NS_CHECK_EXEC([sw01], [ping -q -c 2 -i 0.2 -w 2 > 172.16.1.1 | FORMAT_PING], > AT_CHECK([ovs-vsctl set Open_vSwitch . external-ids:ovn-remote=$SB_PATH]) > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/.*error receiving.*/d > @@ -13593,14 +12970,7 @@ AT_CHECK([ovs-vsctl set Open_vSwitch . > external-ids:ovn-remote=$SB_PATH]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/.*error receiving.*/d > @@ -13740,14 +13110,7 @@ NS_CHECK_EXEC([bar1], [echo "TCP test" | nc -w 1 > --send-only 172.16.1.100 2222]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/.*error receiving.*/d > @@ -13813,14 +13176,7 @@ AT_CHECK([grep -c "NXT_CT_FLUSH_ZONE" > ovs-vswitchd.log], [0], [dnl > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/.*error receiving.*/d > @@ -13908,12 +13264,7 @@ NS_CHECK_EXEC([vm1], [ping -q -c 3 -i 0.3 -w 2 > 172.18.1.12 | FORMAT_PING], \ > 7 packets transmitted, 0 received, 100% packet loss, time 0ms > ]) > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > /connection dropped.*/d"]) > @@ -13974,14 +13325,7 @@ NS_CHECK_EXEC([foo], [arping -q -c 3 > 172.16.1.100]) > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -14107,14 +13451,7 @@ OVS_WAIT_UNTIL([ > > OVS_APP_EXIT_AND_WAIT([ovn-controller]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -14252,14 +13589,7 @@ > tcp,orig=(src=172.16.1.2,dst=192.168.2.2,sport=<cleared>,dport=<cleared>),reply= > > OVN_CLEANUP_CONTROLLER([hv1]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > @@ -14371,14 +13701,7 @@ > icmp,orig=(src=192.168.1.2,dst=192.168.1.1,id=<cleared>,type=8,code=0),reply=(sr > > OVN_CLEANUP_CONTROLLER([hv1]) > > -as ovn-sb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as ovn-nb > -OVS_APP_EXIT_AND_WAIT([ovsdb-server]) > - > -as northd > -OVS_APP_EXIT_AND_WAIT([ovn-northd]) > +OVN_CLEANUP_NORTHD > > as > OVS_TRAFFIC_VSWITCHD_STOP(["/failed to query port patch-.*/d > -- > 2.51.1 > > Thank you Dumitru, I went ahead and merged this into 24.09. Regards, Ales _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev
