On Mon, Sep 25, 2017 at 10:10 AM, Guoshuai Li <l...@dtdream.com> wrote:
> Hi All
>
>
> When the chassis node power off, the south of the database to the Chassis
> table also exists.
>
> For example, the gateway node power off, but the chassis information still
> exists, the traffic continues to forward the package to the chassis.

If you turn on gateway HA, the traffic should move to another host.

> When an external IP address is destroyed, MAC_Binding also has this IP.
>
> For example, the MAC address of the device of the external gateway changes
> (changed one). If there is no external ARP packet, MAC_Binding will not be
> updated.

There is no expiration of MAC_Binding entries.  This needs to be improved.

>
>
> Is there a good way to solve this problem?
>
> please help
>
> Thanks
>
> _______________________________________________
> discuss mailing list
> disc...@openvswitch.org
> https://mail.openvswitch.org/mailman/listinfo/ovs-discuss



-- 
Russell Bryant
_______________________________________________
discuss mailing list
disc...@openvswitch.org
https://mail.openvswitch.org/mailman/listinfo/ovs-discuss

Reply via email to