Here is the log error when I try to add a meter:
#ovs-ofctl -O OpenFlow15 add-meter br0
meter=100,kbps,band=type=drop,rate=300000

Error in ovs-vswitchd.log:
2018-12-28T08:52:06.462Z|00653|connmgr|INFO|br0<->unix#224: sending
OFPMMFC_INVALID_METER error reply to OFPT_METER_MOD message

The kernel verion I updated to is:
#uname -a
Linux ubuntu 4.15.1-041501-generic #201802031831 SMP Sat Feb 3 18:32:13 UTC
2018 x86_64 x86_64 x86_64 GNU/Linux

Could it be that that updating kernel to a supported version i.e. 4.15.1
does not work?


Best Regards,
Ramzah Rehman


On Thu, Dec 27, 2018 at 8:44 PM Ben Pfaff <[email protected]> wrote:

> Check the OVS log for a message that mentions meters.
>
> On Thu, Dec 27, 2018 at 08:30:54PM +0500, Ramzah Rehman wrote:
> > I have Ubuntu 14.04.5 with kernel version 4.4. I updated kernel version
> to
> > 4.15.1 which supports kernel datapaths.
> >
> >  I don't want to use DPDK since I don't have DPDK compatible network
> cards.
> >
> > On Thu, Dec 27, 2018, 8:24 PM Ben Pfaff <[email protected] wrote:
> >
> > > On Thu, Dec 27, 2018 at 12:02:50PM +0500, Ramzah Rehman wrote:
> > > > It is mentioned in FAQ of QoS that "Open vSwitch 2.10 has implemented
> > > > meters in the Linux kernel datapath "  which means we can use meters
> in
> > > > kernel datapath. However, when I try to add meter, I get
> > > > OFPMMFC_INVALID_METER error. This is what I did.
> > > >
> > > > #ovs-vsctl add-br br0
> > > > #ovs-vsctl set bridge br0
> > > >
> > >
> protocols=OpenFlow10,OpenFlow11,OpenFlow12,OpenFlow13,OpenFlow14,OpenFlow15
> > > > #ovs-ofctl -O OpenFlow15 add-meter br0
> > > > meter=100,kbps,band=type=drop,rate=300000
> > > > OFPT_ERROR (OF1.3) (xid=0x2): OFPMMFC_INVALID_METER
> > > > OFPT_METER_MOD (OF1.3) (xid=0x2): ADD meter=100 kbps bands=
> > > > type=drop rate=300000
> > > >
> > > > Please let me what I am doing wrong.
> > >
> > > Probably the kernel module you're using doesn't support meters.
> > >
> > > > One important thing to mention here is that when I set the type of
> > > > switch to netdev like this:
> > > >
> > > > #ovs-vsctl set bridge br0 datapath_type=netdev
> > > >
> > > > I can add meters without any error. What's the reason?
> > >
> > > Each datapath has its own meter implementation, so when you switch
> > > datapaths you get different behavior.
> > >
> > > > There's one problem with this as well, I cannot achieve throughput
> > > > more than 500Mbps on 1Gbps link once I set the datapath type to
> > > > netdev.
> > >
> > > Probably you should use DPDK if you want high performance from the
> > > userspace datapath.
> > >
>
_______________________________________________
discuss mailing list
[email protected]
https://mail.openvswitch.org/mailman/listinfo/ovs-discuss

Reply via email to