Hello,

I'm experiencing packets loss on OpenvSwitch host during transmission to vxlan port under higher traffic load.

Some statistics from 2 machines are here (30 seconds run):

10.10.12.148-ens224-TX 6000025 100 %, 2130008249 bytes
10.10.12.150-ens224-RX 5999429 99 %, 2129796705 bytes
10.10.12.150-vxlan_sys_4789-TX 5641293 94 %, 1923680913 bytes

10.10.12.148 - is traffic generator machine
10.10.12.150 - is OvS host

So as you can see about 5% of traffic is lost on OvS. Does anybody have a clue why this is happening?
More configuration details are below.

Thank you in advance for any help,
Miroslav


/-------------\     /--------------------\
|10.0.0.2     |     |                    |
|       ens224|-----|ens224              |
\_____________/     |                    |
                    |     OVS-host       |
/-------------\     |                    | /---------------------\
|10.0.0.3     |     |      vxlan_sys_4789|--------|vxlan traffix server |
|       ens224|-----|ens256              | |10.10.12.135         |
\_____________/     \____________________/ \_____________________/




$ sudo ovs-vsctl show
68e0245f-1a5f-48ec-a027-a69d839a9b11
    Bridge "br0"
        Controller "tcp:127.0.0.1:6653"
            is_connected: true
        Port "ens256"
            Interface "ens256"
        Port "br0"
            Interface "br0"
                type: internal
        Port vtep
            Interface vtep
                type: vxlan
                options: {key=flow, remote_ip="10.10.12.135"}
        Port "ens224"
            Interface "ens224"
    ovs_version: "2.5.0"

$ sudo ovs-ofctl dump-flows br0 -O OpenFlow13
OFPST_FLOW reply (OF1.3) (xid=0x2):
 cookie=0x0, duration=1265.517s, table=0, n_packets=42029479, n_bytes=14920464750, priority=10000,in_port=10 actions=resubmit(,2)  cookie=0x1, duration=1265.518s, table=0, n_packets=1223020, n_bytes=434172100, priority=1000,udp actions=resubmit(,1)  cookie=0x0, duration=79826.502s, table=0, n_packets=1236672, n_bytes=439008720, priority=10,dl_dst=00:0c:29:42:63:9d actions=output:2  cookie=0x0, duration=79794.509s, table=0, n_packets=46, n_bytes=7757, priority=10,dl_dst=00:0c:29:ec:54:7b actions=output:1  cookie=0x0, duration=79826.501s, table=0, n_packets=11, n_bytes=850, priority=1,in_port=2,dl_dst=00:0c:29:ec:54:7b actions=output:2  cookie=0x0, duration=79836.182s, table=0, n_packets=2, n_bytes=158, priority=0 actions=CONTROLLER:65535  cookie=0x0, duration=1265.517s, table=1, n_packets=49579226, n_bytes=17600625230, actions=output:10  cookie=0x0, duration=79826.501s, table=2, n_packets=42029478, n_bytes=14920464690, priority=100,ip,dl_dst=00:0c:29:42:63:9d actions=output:2  cookie=0x0, duration=79794.509s, table=2, n_packets=0, n_bytes=0, priority=100,ip,dl_dst=00:0c:29:ec:54:7b actions=output:1

$ ovs-vsctl --version
ovs-vsctl (Open vSwitch) 2.5.0
Compiled Apr 28 2016 10:25:38
DB Schema 7.12.1


_______________________________________________
discuss mailing list
[email protected]
https://mail.openvswitch.org/mailman/listinfo/ovs-discuss