It looks like you followed up on this with a patch and that you and Ilya worked it out. If I should look deeper, let me know!
On Sun, May 30, 2021 at 10:40:27PM +0000, Tony van der Peet wrote: > Thanks Ben. I have written a test and can confirm that latest OVS has a > vswitchd crash in this case. After a long chain of calls starting with > handle_packet_out calling ofproto_packet_out_finish, and ending with > dp_netdev_run_meter, dp_packet_delete is called to dispose of the message. > Then handle_packet_out calls ofproto_packet_out_uninit which calls > dp_packet_delete to delete the same message. > > I am a bit stumped as to how to fix this. Stopping the meter code from > deleting the packet would not work for other cases which don't seem to crash, > stopping the packet_out code from deleting the packet would not work for when > the meter is not invoked. Creating a copy of the packet wouldn't work because > it would then have to be disposed of in the normal, non-meter case. Adding > special flags would be a major change, as would reference counting on the > packet buffer. About the best I can think of is a flag to cover this specific > case, maybe added to the packet metadata, which would need to be initialised > false, and then be set true by the packet_out code. Maybe call it > "meter_do_not_delete"? I can try this to see if it works but wonder if > packet_metadata can be altered just like that. Or if there are better ways of > doing this. > > Tony > ________________________________________ > From: Ben Pfaff <[email protected]> > Sent: Saturday, 29 May 2021 5:27 a.m. > To: Tony van der Peet > Cc: [email protected] > Subject: Re: [ovs-discuss] Where does complex packet_out/meters behaviour > test belong? > > On Fri, May 28, 2021 at 05:00:46AM +0000, Tony van der Peet wrote: > > I want to add a unit test that checks what happens when a packet_out > > message with output port OFPP_TABLE is dropped due to the action of a meter > > (our version of vswitchd crashes when I run this test with our oftest > > framework). > > > > > > Where do you suggest I put this test? > > There are a few packet-out tests in > http://scanmail.trustwave.com/?c=20988&d=iKix4E8S7LYunNE_BL4IXm1Ak3fMb7yMJ8K3pmQBJw&u=http%3a%2f%2fofproto-dpif%2eat > perhaps just after > this cluster: > > ofproto-dpif.at:AT_SETUP([ofproto-dpif packet-out controller]) > ofproto-dpif.at:AT_SETUP([ofproto-dpif packet-out controller (patch port)]) > ofproto-dpif.at:AT_SETUP([ofproto-dpif packet-out pipeline match field > (OpenFlow 1.5)]) > ofproto-dpif.at:AT_SETUP([ofproto-dpif packet-out goto_table]) > ofproto-dpif.at:AT_SETUP([ofproto-dpif packet-out table-miss (continue)]) _______________________________________________ discuss mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-discuss