You may want to read http://ip6.com/projects/?p=80
The 1F.xxxxx are the hubs (there are three in the 6 port bus master). 26.7F60B5000000 seems like a humidity sensor, the lightsensor is probably 26.7F60B5000000/vis Be careful, the solar sensor is a real number and you probably need to multiply it by 1000 to get some significant number. If it does not work email me the exact Hobby Boards part numbers and I will try to help -- Silvano On 10/25/11 4:59 PM, pwh wrote: > I have three Hobby Boards units, a serial 6 port bus master, a pressure > sensor, and a solar sensor (recent addition). > One cat5 cable connects the master to the barometer and another the master > to the solar sensor. > I run owfs, then owhttpd. > Browse to localhost:4444 and see three 1F..... addresses. > I don't what the first two are > The third is 1F.3DCF03000000. > I click on it, then on "main" and am taken to a screen which contains > 26.7F60B5000000. > Click on that. On the subsequent screen click on B1-R1-A and the pressure > shows: 1019.27. > > Nowhere do I find the solar sensor. > I don't know if I am running owfs correctly. Is there a document that tells > how to ... run this, then run that, etc? > Any help would be greatly appreciated. > > Thanks, > ------------------------------------------------------------------------------ The demand for IT networking professionals continues to grow, and the demand for specialized networking skills is growing even more rapidly. Take a complimentary Learning@Cisco Self-Assessment and learn about Cisco certifications, training, and career opportunities. http://p.sf.net/sfu/cisco-dev2dev _______________________________________________ Owfs-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/owfs-developers