Ok, I'll concentrate there.

Paul


-----Original Message-----
From: [EMAIL PROTECTED] on behalf of Darryl VanDorp
Sent: Mon 4/3/2006 12:10 AM
To: owfs-developers@lists.sourceforge.net
Subject: Re: [Owfs-developers] ds18s20 reading
 
I just re-read your email. Just to be clear I don't have a problem with the
sensors being discovered, they certainly are being discovered. They are just
not giving a temperature reading (that might be what you meant).

-Darryl

On 4/2/06, Paul Alfille <[EMAIL PROTECTED]> wrote:
>
> Ok, I've spent the last week chaing this down.
>
> 1. We conform to the DS2409 datasheet.
> 2. We use the same algorithm as digitemp (though digitemp only supports
> one level of branching).
> 3. We use the same byte sequence as digitemp.
>
> So what gives?
>
> I noticed a few things
> 1. I wasn't turning off branches properly -- I'll fix
> 2. digitemp doesn't really work either.
>
> Yup. I have a 100 sensors network that is fully discovered in the root
> branch of either digitemp or owfs. Only a few sensors are seen in a main or
> aux branch.
>
> Conclusion -- the 1-wire hubs are poorly suited for multiple sensors.
>
> Next fix attempt -- I'll attempt multiple "discoveries" when working on a
> branch to perhaps get over the problem. Not efficient, but working is
> important.
>
> Paul
>
>
> On 3/30/06, Darryl <[EMAIL PROTECTED]> wrote:
> >
> > I just tried powering the ds18s20 and it made no difference still reads
> > 85. Don't know if that narrows down any variables.....
> >
> >
>


--
http://randomthoughts.vandorp.ca

<<winmail.dat>>

Reply via email to