> I am actually not using the ground pin (I think pin 1) on the sensors
> which
> might be an issue.  I was using it before and not getting any
> exceptions.  I
> will do a test with pin 1 and 3 connected and see the results.
> 

If you don't have any external power connected to the sensors, you have to
connect pin 1 to pin 3 on all sensors to make the parasitic power-mode to
work. Otherwise you will get some random results when reading the
temperatures. (mostly errors which results into 185F)

/Christian



-------------------------------------------------------------------------