Marcus Babzien wrote:
> Hello,
> Is everyone out there doing ethernet 1-wire conversions using an HA7NET? 
>    The LinkHUB-E setup I'm using is very close to a plain vanilla 
> configuration, so I would would have thought someone had issues before.
> -Marcus
> 

Marcus,

I didn't know what to say. I have a linkhub serial and a linkhub-E 
connected to my system. I run owserver to combine the two buses and make 
them available to all the programs, including OWFS. I have mostly 18b20s 
attached (40+) as well as a couple other things.

When I added the linkhub-E, I set up my dhcp server to give it an IP 
address, then I telnetted in. Once that worked, I modified my owserver 
command to include it and it just worked.

Here is my owserver command (x.x.x.x is the assigned ip addres)
/opt/owfs/bin/owserver -d /dev/ttyS0 --LINK x.x.x.x:10001 -p 2840 -P /opt/
owfs/run/owserv.pid


jerry

-------------------------------------------------------------------------