Hello,

>Also comparing your circuit with the one on page 25 of the DS2480B manual

 >http://datasheets.maxim-ic.com/en/ds/DS2480B.pdf

 >you have the POL pin at ground, and they have it at +VDD. Could you have

 >polarity reversed?
That is because the MAX232 has a inverter stage build in and negates the signal 
(Please refer to page 25 figure 11b in 
http://datasheets.maxim-ic.com/en/ds/DS2480B.pdf)

I tried again using an oscilloscope. I see some signal changes on the tx line. 
a) I wonder what to expect
however. A screenshot of an oscilloscope or an equivalent description of the 
detection sequence would be really helpful :-)
b) Looking through the code in  DS2480_detect ( ow_ds9097U.c) suggest that 
there should be some activity on the RX line as well during the detection 
sequence. Is this correct ? 
c) Is there some activity to be expected on the OW bus during the detect 
sequence ?
d) Any suggestions how to narrow this done ? Would it for instance help to 
instrument the detect sequence and see where it bails out ?

Thanks

Tilman