You can use the "simultaneous" conversion -- which can test a large pool of
temperature chips simultaneously. Only with external power. of course.

Paul Alfille

On Mon, Apr 27, 2009 at 5:25 PM, Michael Markstaller <[email protected]> wrote:

> Alarming with the DS18B20 on Temphigh/low works fine with owfs - but I
> guess thats what Jim means -
> only after a conversion was once (manually) initiated. Also unfortunately
> regardless wether they're powered with Vdd or not. Thats IMHO a flaw  with
> the chip, surely not owfs, but it would only make deeper sense if the DS18xx
> would do this by themselves and then alarm.
> So one has to initiate reading the temp anyway, which is the most
> time-consuming part and can use the measured temp directly, alarming is in
> this case, at least in this case for me quite useless ;)
> But now, its still a minor problem 'cause polling the temps is also fine
> within a few seconds..
>
> Michael
>
------------------------------------------------------------------------------
Register Now & Save for Velocity, the Web Performance & Operations 
Conference from O'Reilly Media. Velocity features a full day of 
expert-led, hands-on workshops and two days of sessions from industry 
leaders in dedicated Performance & Operations tracks. Use code vel09scf 
and Save an extra 15% before 5/3. http://p.sf.net/sfu/velocityconf
_______________________________________________
Owfs-developers mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/owfs-developers

Reply via email to