Paul Alfille wrote: > On Thu, Dec 3, 2009 at 8:09 AM, Wolfgang Grandegger > <[email protected]>wrote: > >> This could happen because the address of the bus_master variable >> was pointing to a stack location of the initiating function. >> The problem is fixes by passing the value of bus_master as >> argument. >> >> > Very nice. A pretty subtle bug, and a nice simple solution!
I verified the behavior with a simple test program and unfortunately, it does not fail on my PC/Laptop but just on my ARM i.mx31 board. >> Signed-off-by: Wolfgang Grandegger <[email protected]> >> --- >> >> This fixes one problem. Now I'm facing another one with "owfs" when >> scanning for devices: >> > .... > > This will take some study. Any suggestion? The pipe select does not timeout with owserver. Wolfgang. ------------------------------------------------------------------------------ Join us December 9, 2009 for the Red Hat Virtual Experience, a free event focused on virtualization and cloud computing. Attend in-depth sessions from your desk. Your couch. Anywhere. http://p.sf.net/sfu/redhat-sfdev2dev _______________________________________________ Owfs-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/owfs-developers