Dnia 26-09-2011 o 08:02:52 Don Veino <[email protected]>  
napisaƂ(a):


You can use DS2408 it has 8 IO ports. There are also smaller chips but  
DS2408 is easier to solder.
http://datasheets.maxim-ic.com/en/ds/DS2408.pdf
There's a schematic on page 30. It's parasite powered but if you got  
separate power just instead of the diode bat54 connect +5V
The you can use some kind of switch that would be touched by the door when  
they close. You can also use reed switch and put a magnet on the door.  
There is no physical contact so this switch would be more durable.
http://en.wikipedia.org/wiki/Reed_switch

http://datasheets.maxim-ic.com/en/ds/DS2413.pdf
This also has a schematic on page 1 (left lower corner)



-- 
p4trykx

------------------------------------------------------------------------------