On 19 May 2012, at 22:31, Patryk wrote:

> Dnia 19.05.2012 o 23:24 Stuart Poulton <webw...@gmail.com> Stuart Poulton  
> <webw...@gmail.com> napisaƂ(a):
> 
> Do you think it's possible to connect more than one DS2483 to the same i2c  
> bus? Other masters have lines to select address.

No, in my initial test, my DS2482-100 had it's 2 address lines tied to ground, 
giving an i2c address of 0x18
this is the address that the DS2483 uses, and as you point out there are no 
address select lines on the DS2483

Infact as I mentioned elsewhere OWFS identifies my DS2483 as a DS2482-100 :(

Stuart
------------------------------------------------------------------------------
Live Security Virtual Conference
Exclusive live event will cover all the ways today's security and 
threat landscape has changed and how IT managers can respond. Discussions 
will include endpoint security, mobile security and the latest in malware 
threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/
_______________________________________________
Owfs-developers mailing list
Owfs-developers@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/owfs-developers

Reply via email to