I have several DS18x20 sensors in my network, some DS18S20 (the first 12)
and some DS18B20 (some more added later).

Since i was unsure about some reading of some DS18S20 sensors i used a
second DS18B20 on the same spot...
That reading was about 2°C higher than the DS18S20... i moved it about and
it always was showing +-2°C higher dan the DS18S20 sensor it was next.
All these sensors are parasite powered.
After this i retried it with another DS18S20 (connected to the +5V - no
parasite power) and this one was 2.5°C higher dan the DS18B20...

The DS18B20 are sampled directly from maxim, thus should be genuine. The
DS18S20: some are samples from Maxim, and others i bought of ebay.

Does anyone know why there is is such a difference? (and mabe a solution?)



------------------------------------------------------------------------------