>If you really need a tree, you have to put a DS2409 bus coupler on each fork. Usually it is simpler to create an electrical bus without >leaves by making lobes of 1wire+GND forward and 1wire+GND return wires to the remote locations. >> >> The problem that i am experiencing is that when i read the value of >> the counters via the command line, owfs crashes sometimes (not always >> at the same time). I can solve it by killing it and restarting >> >Start it with --debug and see what it says when crashing.
>Kind regards > Jan Sadly it seems that the DS2409 is no longer available, so i have to make it more like a *bus*. But by doing this (i think) i will lose the "easy" connection though the rj45 hub ports: every port needs to be connected, otherwhise the signal ends. Is there any known number of DS18.20 (or length of cat5e cable) that will work without any problems in a tree like network? That would limit the resoldering i need to do. I have "a feeling" that the counter modules generate the most problems, is this true? thanks in advance Jan PS does anyone know where to get the DS2409 (for a reasonable price) ------------------------------------------------------------------------------ Learn Graph Databases - Download FREE O'Reilly Book "Graph Databases" is the definitive new guide to graph databases and their applications. Written by three acclaimed leaders in the field, this first edition is now available. Download your free book today! http://p.sf.net/sfu/13534_NeoTech _______________________________________________ Owfs-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/owfs-developers