There's a command to convert temperature of all sensors in the bus, that's
the simultaneous conversion
Check owfs file system there's a file just for this
Check ds1820 datasheet too , that's interesting when you need speed

Em terça-feira, 28 de outubro de 2014, Coudy <co...@chovan.net> escreveu:

> Hi, what do you mean with "do a simultaneous conversion and read the
> values after the conversion is done on all sensors." ?
> Could you please add example ?
> I read data with cat /mountpoint/sensor/temperature.
>
> If temperature sensor is powered, then reading is faster compared to
> parasitic power ?
>
>
> 2014-10-28 11:40 GMT+01:00 Jan Kandziora <j...@gmx.de
> <javascript:_e(%7B%7D,'cvml','j...@gmx.de');>>:
>
>> Am 27.10.2014 um 18:08 schrieb Coudy:
>> > I have in Zabbix Timeout 15 seconds. I want to try restart server every
>> > hour, then I'll post results
>> >
>> Sampling 19 temperature sensors one-by-one takes up to 19 seconds. This
>> is due to the lengthy A/D conversion process.
>>
>> Either increase the timeout, sample 9-bit or 10-bit only, or power the
>> sensors, then do a simultaneous conversion and read the values after the
>> conversion is done on all sensors. The latter takes about 2 seconds for
>> 20 sensors in 12-Bit mode on a DS9097.
>>
>> Kind regards
>>
>>         Jan
>>
>>
>>
>>
>> ------------------------------------------------------------------------------
>> _______________________________________________
>> Owfs-developers mailing list
>> Owfs-developers@lists.sourceforge.net
>> <javascript:_e(%7B%7D,'cvml','Owfs-developers@lists.sourceforge.net');>
>> https://lists.sourceforge.net/lists/listinfo/owfs-developers
>>
>
>

-- 
Roberto Spadim
SPAEmpresarial
Eng. Automação e Controle
------------------------------------------------------------------------------
_______________________________________________
Owfs-developers mailing list
Owfs-developers@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/owfs-developers