First note that it only works if the sensors are powered.
I use it in my system and it works well. The sequence of operations is -
Read all sensors
Write '1' to simultaneous/temperature register
Perform the control logic
Write to the outputs
Repeat
Writing to simultaneous/temperature causes the sensors to perform the
temperature calculations, so when I read again next cycle the values are
ready.
My system has 8 channels and each one has a simultaneous/temperature
register, I don't know if it is necessary but I write to all of them, it
doesn't take much time for the write.
Hope that helps
Mick
On 26/05/15 19:16, Roland Franke wrote:
Hello,
in combination of the owfs/owserver and collectd is by the collectd
daemon an fast reading from values directly over the owcapi installed
in the onewire plugin of collectd.
The question is now, if there is any way to activate the simultaneous
value for temperature/soltage by each reading-cycle?
Best regards,
Roland
------------------------------------------------------------------------------