Dear all,

I know this is not a common owfs problem, but I would like to know some 
information about the communication to the ds2450 and how to debug it 
with the owserver.

Wright now I am working on a Ds2450 Slave, based on a attiny45 and
I get the values "Error: Invalid argument" on "PIO.*" and "volt.*" shown 
as values in the webpage of the owserver.

The "memory" is shown the value 
"0000000000000000008000800080008000FF00FF00FF00FF0000000040000000"

and I do not know how to find the reason, because Memory transfer is 
working so far i can see correctly (used values of 1.. 31 and checked it 
on the "page" infos).


I also noticed, that the command "CONVERT" (0x3C)  was not send to the 
slave (or was not recognize), which I guess is my fault, but where do I 
have to take a closer look. I do not have a logic analyser to get closer.

I also try to show the communication of the owserver, but I do
not see any entries on the console.

I used the command:

sudo /usr/bin/owserver --foreground --error_print=0 --error_level=9 -c 
/etc/owfs.conf


Can anybody help me ?

Best regards

R.


------------------------------------------------------------------------------