Dear all, I know this is not a common owfs problem, but I would like to know some information about the communication to the ds2450 and how to debug it with the owserver.
Wright now I am working on a Ds2450 Slave, based on a attiny45 and I get the values "Error: Invalid argument" on "PIO.*" and "volt.*" shown as values in the webpage of the owserver. The "memory" is shown the value "0000000000000000008000800080008000FF00FF00FF00FF0000000040000000" and I do not know how to find the reason, because Memory transfer is working so far i can see correctly (used values of 1.. 31 and checked it on the "page" infos). I also noticed, that the command "CONVERT" (0x3C) was not send to the slave (or was not recognize), which I guess is my fault, but where do I have to take a closer look. I do not have a logic analyser to get closer. I also try to show the communication of the owserver, but I do not see any entries on the console. I used the command: sudo /usr/bin/owserver --foreground --error_print=0 --error_level=9 -c /etc/owfs.conf Can anybody help me ? Best regards R. ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, SlashDot.org! http://sdm.link/slashdot _______________________________________________ Owfs-developers mailing list Owfs-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/owfs-developers