Am 20.01.2018 um 00:35 schrieb Péter Zsembery:
> Hi All,
> I am trying to read the counter values of two DS2423 1-wire counters with
> OWFS 3.2p1. The OWHTTPD always returns "Error: Invalid argument" for the
> following parameters:
> counter.ALL
> counter.A
> counter.B
> memory
> mincount
> pages/
> The other parameters are correct.
> The wiring is double checked. Seems to be OK.
>
Is Vbat connected to a 2.8..5V source? The DS2423 parasite powered
circuitry does provide power to all the ROM function components but as
soon the RAM or counters should be accessed, you need Vbat.

Kind regards

        Jan

------------------------------------------------------------------------------