Hello!

Thanks Sorin. This was exactly what I was looking for!

Br,
Jan

On 13 aug 2009, at 18.22, Sorin Ristache wrote:

Oxygen sets the value of the parameter -DHTMLHelpCompiler to the result
of the concatenation of the Windows registry value "Path" from the
registry key

"HKEY_LOCAL_MACHINE\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\App
Paths\\hhw.exe"

If this "Path" value is not set in the registry Oxygen assumes that the
HTML Help Workshop is not installed on the computer and displays the
following transformation warning:


HTML Help Workshop not detected. You must install it to be able to
create CHM files.


I think in your case the registry value contains the path "C:\Program
Files\Help Workshop" and it was set by a previous installation of the
HTML Help Workshop and now there is a newer version installed in
"C:\Program Files\HTML Help Workshop" but the registry value remained
the old one. Please set the correct path to hhc.exe manually in the
above Windows registry key. For the next version of Oxygen we will check
what should be the path set in registry by the latest version of the
Microsoft Help system.


Best regards,
Sorin


--
Jan Nylund
Senior System Designer
Citec Information Oy Ab

Attachment: smime.p7s
Description: S/MIME cryptographic signature

_______________________________________________
oXygen-user mailing list
[email protected]
http://www.oxygenxml.com/mailman/listinfo/oxygen-user

Reply via email to