Hi Andrew, About the cause of this problem, did you understand what it was?
Please contact me if there is the information that is necessary for investigation else. Best Regards, Hideo Yamauchi. --- renayama19661...@ybb.ne.jp wrote: > Hi Andrew, > > I confirmed it in the next environment. > > * CentOS 5.4 (on ESXi) > * Pacemaker-1-0-0bf7d14dd554 > * Cluster-Resource-Agents-a3db4fe39301 > * Reusable-Cluster-Components-f547243d9245 > * corosync-1.2.0 > > I attach a result of hb_report as a result of cibadmin when a problem > occurred. > > Please teach it if you understand the cause of the problem. > > Best Regards, > Hideo Yamauchi. > > > --- Andrew Beekhof <and...@beekhof.net> wrote: > > > On Thu, Feb 11, 2010 at 1:52 AM, <renayama19661...@ybb.ne.jp> wrote: > > > Hi Andrew, > > > > > > Thank you for comment. > > > > > >> Actually, none of the included pe files seem to match the failure > > >> case... can you supply the cib from that condition? > > > > > > I report the result that carried out cibadmin -Q at the stage of each > > > problem. > > > Is this information(cibadmin -Q) enough? > > > > Yes, that would be enough for me to investigate. > > > > _______________________________________________ > > Pacemaker mailing list > > Pacemaker@oss.clusterlabs.org > > http://oss.clusterlabs.org/mailman/listinfo/pacemaker > > > > <cib validate-with="pacemaker-1.0" crm_feature_set="3.0.1" have-quorum="1" > > dc-uuid="srv02" > admin_epoch="0" epoch="130" num_updates="5"> > <configuration> > <crm_config> > <cluster_property_set id="cib-bootstrap-options"> > <nvpair id="cib-bootstrap-options-no-quorum-policy" > name="no-quorum-policy" > value="freeze"/> > <nvpair id="cib-bootstrap-options-stonith-enabled" > name="stonith-enabled" value="true"/> > <nvpair id="cib-bootstrap-options-startup-fencing" > name="startup-fencing" > value="false"/> > <nvpair id="cib-bootstrap-options-stonith-timeout" > name="stonith-timeout" value="430s"/> > <nvpair id="cib-bootstrap-options-dc-deadtime" name="dc-deadtime" > value="48s"/> > <nvpair id="cib-bootstrap-options-dc-version" name="dc-version" > value="1.0.7-0bf7d14dd5541b31f7dee605e5041bb44d78b336"/> > <nvpair id="cib-bootstrap-options-cluster-infrastructure" > name="cluster-infrastructure" > value="openais"/> > <nvpair id="cib-bootstrap-options-expected-quorum-votes" > name="expected-quorum-votes" > value="4"/> > </cluster_property_set> > </crm_config> > <rsc_defaults> > <meta_attributes id="rsc_defaults-meta_attributes"> > <nvpair id="rsc-default-meta_attributes-resource-stickiness" > name="resource-stickiness" > value="100"/> > <nvpair id="rsc-default-meta_attributes-migration-threshold" > name="migration-threshold" > value="1"/> > </meta_attributes> > </rsc_defaults> > <nodes> > <node id="srv01" uname="srv01" type="normal"/> > <node id="srv02" uname="srv02" type="normal"/> > <node id="srv03" uname="srv03" type="normal"/> > <node id="srv04" uname="srv04" type="normal"/> > </nodes> > <resources> > <group id="UMgroup01"> > <primitive class="ocf" type="Dummy" provider="heartbeat" > id="UmVIPcheck"> > <operations> > <op id="op-umVIPcheck-start" interval="0" name="start" > timeout="90s" > on-fail="restart" start-delay="2s"/> > </operations> > </primitive> > <primitive class="ocf" type="Dummy" provider="heartbeat" > id="UmIPaddr"> > <operations> > <op id="op-umIPaddr-start" interval="0" name="start" > timeout="60s" on-fail="restart" > requires="fencing"/> > <op id="op-umIPaddr-monitor" interval="10" name="monitor" > timeout="60s" > on-fail="restart"/> > <op id="op-umIPaddr-stop" interval="0" name="stop" timeout="60s" > on-fail="block"/> > </operations> > </primitive> > <primitive class="ocf" type="Dummy" provider="heartbeat" > id="UmDummy01"> > <operations> > <op id="op-umdummy01-start" interval="0" name="start" > timeout="60s" > on-fail="restart" requires="fencing"/> > <op id="op-umdummy01-monitor" interval="10" name="monitor" > timeout="60s" > on-fail="ignore"/> > <op id="op-umdummy01-stop" interval="0" name="stop" timeout="60s" > on-fail="stop"/> > </operations> > </primitive> > <primitive class="ocf" type="Dummy" provider="heartbeat" > id="UmDummy02"> > <operations> > <op id="op-umdummy02-start" interval="0" name="start" > timeout="60s" > on-fail="standby" requires="fencing"/> > <op id="op-umdummy02-monitor" interval="10" name="monitor" > timeout="60s" > on-fail="standby"/> > <op id="op-umdummy02-stop" interval="0" name="stop" timeout="60s" > on-fail="block"/> > </operations> > </primitive> > </group> > <group id="OVDBgroup02-1"> > <primitive class="ocf" id="prmExPostgreSQLDB1" provider="heartbeat" > type="Dummy"> > <operations> > <op id="prmExPostgreSQLDB1-start" interval="0" name="start" > on-fail="restart" > timeout="300s"/> > <op id="prmExPostgreSQLDB1-monitor" interval="10s" name="monitor" > on-fail="restart" > timeout="90s"/> > <op id="prmExPostgreSQLDB1-stop" interval="0" name="stop" > on-fail="fence" > timeout="60s"/> > </operations> > </primitive> > <primitive class="ocf" id="prmFsPostgreSQLDB1-1" provider="heartbeat" > type="Dummy"> > <operations> > <op id="prmFsPostgreSQLDB1-1-start" interval="0" name="start" > on-fail="restart" > timeout="60s"/> > <op id="prmFsPostgreSQLDB1-1-monitor" interval="10s" > name="monitor" > on-fail="restart" timeout="60s"/> > <op id="prmFsPostgreSQLDB1-1-stop" interval="0" name="stop" > on-fail="fence" > timeout="60s"/> > </operations> > </primitive> > <primitive class="ocf" id="prmFsPostgreSQLDB1-2" provider="heartbeat" > type="Dummy"> > <operations> > <op id="prmFsPostgreSQLDB1-2-start" interval="0" name="start" > on-fail="restart" > timeout="60s"/> > <op id="prmFsPostgreSQLDB1-2-monitor" interval="10s" > name="monitor" > on-fail="restart" timeout="60s"/> > <op id="prmFsPostgreSQLDB1-2-stop" interval="0" name="stop" > on-fail="fence" > timeout="60s"/> > </operations> > </primitive> > <primitive class="ocf" id="prmFsPostgreSQLDB1-3" provider="heartbeat" > type="Dummy"> > <operations> > <op id="prmFsPostgreSQLDB1-3-start" interval="0" name="start" > on-fail="restart" > timeout="60s"/> > <op id="prmFsPostgreSQLDB1-3-monitor" interval="10s" > name="monitor" > on-fail="restart" timeout="60s"/> > <op id="prmFsPostgreSQLDB1-3-stop" interval="0" name="stop" > on-fail="fence" > timeout="60s"/> > </operations> > </primitive> > <primitive class="ocf" id="prmIpPostgreSQLDB1" provider="heartbeat" > type="Dummy"> > <operations> > <op id="prmIpPostgreSQLDB1-start" interval="0" name="start" > on-fail="restart" > timeout="60s"/> > <op id="prmIpPostgreSQLDB1-monitor" interval="10s" name="monitor" > on-fail="restart" > timeout="60s"/> > <op id="prmIpPostgreSQLDB1-stop" interval="0" name="stop" > on-fail="fence" > timeout="60s"/> > </operations> > </primitive> > <primitive class="ocf" id="prmApPostgreSQLDB1" provider="heartbeat" > type="Dummy"> > <operations> > <op id="prmApPostgreSQLDB1-start" interval="0" name="start" > on-fail="restart" > timeout="300s"/> > <op id="prmApPostgreSQLDB1-monitor" interval="10s" name="monitor" > on-fail="restart" > timeout="60s"/> > <op id="prmApPostgreSQLDB1-stop" interval="0" name="stop" > on-fail="fence" > timeout="300s"/> > </operations> > </primitive> > </group> > <group id="OVDBgroup02-2"> > <primitive class="ocf" id="prmExPostgreSQLDB2" provider="heartbeat" > type="Dummy"> > <operations> > <op id="prmExPostgreSQLDB2-start" interval="0" name="start" > on-fail="restart" > timeout="300s"/> > <op id="prmExPostgreSQLDB2-monitor" interval="10s" name="monitor" > on-fail="restart" > timeout="90s"/> > <op id="prmExPostgreSQLDB2-stop" interval="0" name="stop" > on-fail="fence" > timeout="60s"/> > </operations> > </primitive> > <primitive class="ocf" id="prmFsPostgreSQLDB2-1" provider="heartbeat" > type="Dummy"> > <operations> > <op id="prmFsPostgreSQLDB2-1-start" interval="0" name="start" > on-fail="restart" > timeout="60s"/> > <op id="prmFsPostgreSQLDB2-1-monitor" interval="10s" > name="monitor" > on-fail="restart" timeout="60s"/> > <op id="prmFsPostgreSQLDB2-1-stop" interval="0" name="stop" > on-fail="fence" > timeout="60s"/> > </operations> > </primitive> > <primitive class="ocf" id="prmFsPostgreSQLDB2-2" provider="heartbeat" > type="Dummy"> > <operations> > <op id="prmFsPostgreSQLDB2-2-start" interval="0" name="start" > on-fail="restart" > timeout="60s"/> > <op id="prmFsPostgreSQLDB2-2-monitor" interval="10s" > name="monitor" > on-fail="restart" timeout="60s"/> > <op id="prmFsPostgreSQLDB2-2-stop" interval="0" name="stop" > on-fail="fence" > timeout="60s"/> > </operations> > </primitive> > <primitive class="ocf" id="prmFsPostgreSQLDB2-3" provider="heartbeat" > type="Dummy"> > <operations> > <op id="prmFsPostgreSQLDB2-3-start" interval="0" name="start" > on-fail="restart" > timeout="60s"/> > <op id="prmFsPostgreSQLDB2-3-monitor" interval="10s" > name="monitor" > on-fail="restart" timeout="60s"/> > <op id="prmFsPostgreSQLDB2-3-stop" interval="0" name="stop" > on-fail="fence" > timeout="60s"/> > </operations> > </primitive> > <primitive class="ocf" id="prmIpPostgreSQLDB2" provider="heartbeat" > type="Dummy"> > <operations> > <op id="prmIpPostgreSQLDB2-start" interval="0" name="start" > on-fail="restart" > timeout="60s"/> > <op id="prmIpPostgreSQLDB2-monitor" interval="10s" name="monitor" > on-fail="restart" > timeout="60s"/> > <op id="prmIpPostgreSQLDB2-stop" interval="0" name="stop" > on-fail="fence" > timeout="60s"/> > </operations> > </primitive> > <primitive class="ocf" id="prmApPostgreSQLDB2" provider="heartbeat" > type="Dummy"> > <operations> > <op id="prmApPostgreSQLDB2-start" interval="0" name="start" > on-fail="restart" > timeout="300s"/> > <op id="prmApPostgreSQLDB2-monitor" interval="10s" name="monitor" > on-fail="restart" > timeout="60s"/> > <op id="prmApPostgreSQLDB2-stop" interval="0" name="stop" > on-fail="fence" > timeout="300s"/> > </operations> > </primitive> > </group> > <group id="OVDBgroup02-3"> > <primitive class="ocf" id="prmExPostgreSQLDB3" provider="heartbeat" > type="Dummy"> > <operations> > <op id="prmExPostgreSQLDB3-start" interval="0" name="start" > on-fail="restart" > timeout="300s"/> > <op id="prmExPostgreSQLDB3-monitor" interval="10s" name="monitor" > on-fail="restart" > timeout="90s"/> > === 以下のメッセージは省略されました ===> _______________________________________________ > Pacemaker mailing list > Pacemaker@oss.clusterlabs.org > http://oss.clusterlabs.org/mailman/listinfo/pacemaker > _______________________________________________ Pacemaker mailing list Pacemaker@oss.clusterlabs.org http://oss.clusterlabs.org/mailman/listinfo/pacemaker