On 27 October 2010 13:12, Vadym Chepkov <vchep...@gmail.com> wrote:
>
> On Oct 27, 2010, at 3:47 AM, Pavlos Parissis wrote:
>>
>> Does anyone know any other PDU which works out of box with the
>> supplied stonith agents?
>>
>
> I use APC AP7901, works like a charm:
>
> primitive pdu stonith:external/rackpdu \
>        params pduip="10.6.6.6" community="pdu-6" hostlist="AUTO"
> clone fencing pdu
>
> Vadym

Then most likely the defaults OIDs of the rackpdu agents matches the
OIDs of the AP7901.
In my case I have to use OID for the device itself
1.3.6.1.4.1.318.1.1.4.4.2.1.3  and OID for retrieving (snmpwalk) the
outlet list .1.3.6.1.4.1.318.1.1.4.4.2.1.4 .

Hold on a sec, are you using clone on AP7901? Does it support multiple
connections? Mine it doesn't.

Cheers,
Pavlos

_______________________________________________
Pacemaker mailing list: Pacemaker@oss.clusterlabs.org
http://oss.clusterlabs.org/mailman/listinfo/pacemaker

Project Home: http://www.clusterlabs.org
Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf
Bugs: http://developerbugs.linux-foundation.org/enter_bug.cgi?product=Pacemaker