On 2011-01-12T22:52:14, Bart Coninckx <bart.conin...@telenet.be> wrote:
> Jan 12 22:20:34 xen2 pengine: [6633]: WARN: unpack_rsc_op: Processing failed > op intranet1_stop_0 on xen1: unknown exec error (-2) > My monitors are set to restart a resorce. What makes the PE decide to fence > the node in stead of first trying to restart the resource as the monitor > operation is configured to do? The restart consists of a "stop" and a "start"; as you can see from the above logs, the "stop" failed. Regards, Lars -- Architect Storage/HA, OPS Engineering, Novell, Inc. SUSE LINUX Products GmbH, GF: Markus Rex, HRB 16746 (AG Nürnberg) "Experience is the name everyone gives to their mistakes." -- Oscar Wilde _______________________________________________ Pacemaker mailing list: Pacemaker@oss.clusterlabs.org http://oss.clusterlabs.org/mailman/listinfo/pacemaker Project Home: http://www.clusterlabs.org Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf Bugs: http://developerbugs.linux-foundation.org/enter_bug.cgi?product=Pacemaker