Hi-

I have my cluster configured to use a cloned ping resource, such that I can write a constraint that I prefer resources to run on a node that has network connectivity. That works fine if a machine loses its network connection (the ping attribute goes to 0, resources migrate to another machine, etc.).

However, if instead what happens is the ping /target/ goes offline, it seems that Pacemaker will bounce resources around the cluster, as each node notices that the ping target is unreachable at a slightly different time.

Is there any way to get Pacemaker to delay resource transitions until at least one full polling cycle has happened, so that in the event of an outage of the ping target, resources stay put where they are running?

--Quentin

_______________________________________________
Pacemaker mailing list: Pacemaker@oss.clusterlabs.org
http://oss.clusterlabs.org/mailman/listinfo/pacemaker

Project Home: http://www.clusterlabs.org
Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf
Bugs: http://bugs.clusterlabs.org