On 2013-11-19T09:27:10, "Angel L. Mateo" <[email protected]> wrote:

> property $id="cib-bootstrap-options" \
>         dc-version="1.1.6-9971ebba4494012a93c03b40a2c58ec0eb60f50c" \

Wow, that's quite old.

> Nov 16 12:20:47 myotis51 sbd: [1377]: WARN: Latency: No liveness for 4 s
> exceeds threshold of 3 s (
> healthy servants: 0)
> 
>       Should I stop sbd daemon even if I have stonith-enabled=false?

stonith-enabled="false" does not disable sbd's self-fencing in case of
lost devices. (I think I'd be willing to take a patch if it isn't too
convoluted.)

You may want to consider using the -P option to enable pacemaker
integration though; that could also make things better.

Note that not running the sbd daemon and setting stonith-enabled="true"
again will yield false STONITH successes. You're really not encouraged
to do that, or only very carefully.



Regards,
    Lars

-- 
Architect Storage/HA
SUSE LINUX Products GmbH, GF: Jeff Hawn, Jennifer Guild, Felix Imendörffer, HRB 
21284 (AG Nürnberg)
"Experience is the name everyone gives to their mistakes." -- Oscar Wilde


_______________________________________________
Pacemaker mailing list: [email protected]
http://oss.clusterlabs.org/mailman/listinfo/pacemaker

Project Home: http://www.clusterlabs.org
Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf
Bugs: http://bugs.clusterlabs.org

Reply via email to