Please see:

https://access.redhat.com/site/articles/36302

If you don't have an account, the relevant part is:

"Usage of fence_manual is not supported in any production cluster. You may use this fence agent for development or debugging purposes only."

I wrote about fence_ack_manual, not about fence_manual. fence_ack_manual isn't a fence agent, it's confirmation tool like stonith_admin -C.
2. Pacemaker notifies CMAN about  real fencing, why not about manual
confirmations? It's bug, i'm sure.

Perhaps, I can't speak to pacemaker's behaviour.
Ok. I'll think that it's not a bug, but feature request.

3. I use real fencing. Manual fencing needed in rare situations, like
problem with IPMI controller, lost power or so. What should
administrator do without manual confirmations? :)

Fencing should loop until it succeeds. Fix the problem, fence_ack_manual if that's not possible or, ideally, use multiple fence methods (I use IPMI on one switch and switched PDUs on another switch for redundancy).

I have two datacenters joined with fast links, i have syncronous replication so server groups in two separate datacenters forms clusters. if one campus burned with own fencing devices in a whole how i must fix this? In some situations administrator needs of simple and fast manual confirmation or it's not a high availability.