Hi Brent,

>
> Since I am only using MAB,

Ok, if you are using MAB, then this whole thread is in the wrong direction.

In MAB, the client doesn't speak EAPoL so there's no way to flip the 
VLAN in a dialog between the switch and the client.

When a port is in MAB, PacketFence will bounce the port (shut, wait, 
no-shut) instead of doing the PAE-Reauth you guys were talking about.

May I stress on the fact that you must *make sure* that your homemade 
NAS-Port to ifIndex works appropriately (by walking the IF-MIB and 
comparing with what's in pf's locationlog table).

What do you have in the packetfence logs when PacketFence wants to 
change the user's VLAN? Sorry if you already sent it before..

Thanks,
-- 
Olivier Bilodeau
[email protected]  ::  +1.514.447.4918 *115  ::  www.inverse.ca
Inverse inc. :: Leaders behind SOGo (www.sogo.nu) and PacketFence 