Good Morning,
I have PacketFence running and for the most part is working flawlessly.
However I am experiencing three issues that I can’t seem to resolve.
Issue 1 – Since upgrading to the latest version, my MAC Vendor List is blank.
No nodes report their MAC vendor when I look at the node details. I have
performed several resolutions I have received here and it doesn’t update the
table. At times in my packetfence.log file I see:
Jan 15 22:54:29 httpd.webservices(21652) INFO: loading Net::MAC::Vendor cache
from /usr/local/pf/conf/oui.txt (pf::util::load_oui)
However the list is still blank.
Issue 2 – There are some cases on my network where a user will have a small
netgear 4 port switch to connect a printer or another PC. PacketFence shows
this in the log:
Jan 15 22:54:49 pfsetvlan(2) WARN: couldn't get MAC at ifIndex 10112. This is a
problem. (pf::Switch::_getMacAtIfIndex)
It will display that 30 times before it stops trying. I am guessing that due
to the small switch there and it’s unmanaged that packetfence either cannot
find a locationlog entry or that switch isn’t reporting a MAC address to the
managed switch.
Is there a way around this without compromising that port and telling
packetfence not to manage that port?
Issue 3 – PacketFence isn’t ignoring uplink ports on switches.
All uplink ports are set to 802.1Q Trunk
Snippet from switches.conf:
[***.***.***.***]
RoleMap=N
wsPwd=*********
SNMPCommunityRead=********
guestVlan=99
SNMPCommunityWrite=********
cliUser=********
defaultVlan=1
SNMPUserNameTrap=********
wsTransport=HTTPS
deauthMethod=SNMP
description=Switch_A
type=Cisco::Catalyst_2960
macDetectionVlan=20
cliPwd=********
VoIPEnabled=N
isolationVlan=99
cliTransport=SSH
uplink_dynamic=0
cliEnablePwd=********
uplink=1,5,23,24
SNMPCommunityTrap=********
wsUser=********
registrationVlan=20
inlineVlan=1
registeredVlan=7
SNMPUserNameWrite=********
SNMPEngineID=local
SNMPUserNameRead=********
SNMPAuthProtocolRead=md5
SNMPPrivPasswordTrap=********
SNMPAuthProtocolTrap=MD5
SNMPAuthProtocolWrite=md5
SNMPPrivPasswordRead=********
SNMPPrivProtocolWrite=aes
SNMPAuthPasswordWrite=********
SNMPPrivPasswordWrite=********
SNMPAuthPasswordRead=********
SNMPPrivProtocolTrap=AES
SNMPPrivProtocolRead=aes
SNMPAuthPasswordTrap=********
mode=production
AccessListMap=N
Example:
Switch A: 24 port Cisco 2960, Ports 1,5,23,24 are uplinks, primary switch.
Uplink map: 24 – Internet source
23 – Redundant Internet source (disabled)
1 – Switch B
7 – Switch D
Switch B: 24 port Cisco 2960, Ports 23.24 are uplinks. Secondary Switch.
Uplink map: 24 – Uplink to Switch A
23 – Uplink to Switch C
Switch C: 24 port Cisco 2960, Ports 24 is uplink. Secondary Switch.
Uplink map: 24 – Uplink to Switch C
Switch D: 24 port Cisco 2960, Ports 24 is uplink. Secondary Switch.
Uplink map: 24 – Uplink to Switch A
When I connect any secondary switch, PacketFence changes the ports Native Vlan
to registration on the parent switch. I can’t get it to stop changing the
uplinks. Any ideas?
Thanks in Advanced!
Scott
------------------------------------------------------------------------------
New Year. New Location. New Benefits. New Data Center in Ashburn, VA.
GigeNET is offering a free month of service with a new server in Ashburn.
Choose from 2 high performing configs, both with 100TB of bandwidth.
Higher redundancy.Lower latency.Increased capacity.Completely compliant.
http://p.sf.net/sfu/gigenet
_______________________________________________
PacketFence-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/packetfence-users