We have seen many issues like these, but not anymore since 5.3 On vesions earlier, the netns became disfunctional after clicking the status / services gui.
What version are you on? Sent by MailWise – See your emails as clean, short chats. -------- Original Message -------- From: "Sallee, Jake" <[email protected]> Sent: Thursday, August 20, 2015 06:34 PM To: "[email protected] " <[email protected]> Subject: Re: [PacketFence-users] Error in GUI domain config >So, a configreload hard and blanking out my domain.conf file seemed to help. > >I can get to the domain GUI now ... so I've got that going for me ... which is >nice. > >I still cant get the server to join the AD though. > >here is the log: > >[2015/08/20 11:25:21, 0] winbindd/winbindd.c:1382(main) > winbindd version 3.6.23-14.el6_6 started. > Copyright Andrew Tridgell and the Samba Team 1992-2011 >[2015/08/20 11:25:21.669918, 0] >winbindd/winbindd_cache.c:3203(initialize_winbindd_cache) > initialize_winbindd_cache: clearing cache and re-creating with version > number 2 >[2015/08/20 11:25:21.672218, 0] winbindd/winbindd_util.c:630(init_domain_list) > Could not fetch our SID - did we join? >[2015/08/20 11:25:21.672305, 0] >winbindd/winbindd.c:1142(winbindd_register_handlers) > unable to initialize domain list > >Not too helpful AFAICT. > >when I do a net ads info I get: > >ads_connect: No logon servers >ads_connect: No logon servers >Didn't find the ldap server! > >But I have made sure the servers are active, running, and accessible by my PF >server. > >Ideas? Deep theological insights? > >Jake Sallee >Godfather of Bandwidth >System Engineer >University of Mary Hardin-Baylor >WWW.UMHB.EDU > >900 College St. >Belton, Texas >76513 > >Fone: 254-295-4658 >Phax: 254-295-4221 > >________________________________________ >From: Sallee, Jake [[email protected]] >Sent: Thursday, August 20, 2015 10:50 AM >To: [email protected] >Subject: [PacketFence-users] Error in GUI domain config > >Hello all! > >Im trying to join my server to my AD domain, however it gave me an error about >not finding my info over rpc. > >However now when I go to the domain config section of the admin GUI i get the >red "An error occurred" dialogue. > >Can someone please post a working (and sanitized) copy of their domain.conf so >I can get this back up and running, my students are getting antsy : ) > >Also, I have already restarted the PF services to see if I could get back to >the GUI domains config, but no luck. Any ideas on how I can get that part of >the admin interface working again are welcome. > >Another weird thing is that I noticed winbindd no longer shows up in the list >of restart-able services in the web admin GUI, no idea if that is related. > >Jake Sallee >Godfather of Bandwidth >System Engineer >University of Mary Hardin-Baylor >WWW.UMHB.EDU > >900 College St. >Belton, Texas >76513 > >Fone: 254-295-4658 >Phax: 254-295-4221 > >------------------------------------------------------------------------------ >_______________________________________________ >PacketFence-users mailing list >[email protected] >https://lists.sourceforge.net/lists/listinfo/packetfence-users > >------------------------------------------------------------------------------ >_______________________________________________ >PacketFence-users mailing list >[email protected] >https://lists.sourceforge.net/lists/listinfo/packetfence-users
------------------------------------------------------------------------------
_______________________________________________ PacketFence-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/packetfence-users