Thanks Stephen and John for your quick answers. Unfortunately any changes to the group and/or part tag not seem to solve the problem. What is strange is that, although ParaView seems to read an int value, it is able to handle
<DataSet timestep="-922337203685477580825263735124730" group="" part="0" file="sp_test0000000.vtp"/> <DataSet timestep=" 922337203685477580825263735124730" group="" part="0" file="sp_test0002498.vtp"/> correctly, what gives me Index Value 0 -9.22337e+32 1 9.22337e+32 in the time table although the values are out of range of any standard integer representation I guess. However, as a workaround -considering the large range of representable integer values- I will simpliy change my scale to micro- or even nano-seconds to get integer time values. 2009/1/29 John Biddiscombe <[email protected]>: > Christian > > <?xml version="1.0"?> > <VTKFile type="Collection" version="0.1" byte_order="LittleEndian"> > <Collection> > <DataSet timestep="1.08267" file="1800_001-static-00000.vtmb"/> > <DataSet timestep="1.08367" file="1800_001-static-00001.vtmb"/> > <DataSet timestep="1.08467" file="1800_001-static-00002.vtmb"/> > ... > <DataSet timestep="1.34967" file="1800_001-static-00267.vtmb"/> > </Collection> > </VTKFile> > > This works for me. Can't comment on why you are having trouble, but maybe > try to remove the group, part unused tags. > > I use CVS paraview (3.4 should work) > > JB > >> Dear all, >> >> I'm using ParaView 3.4 to load the results of a transient simulation >> via a pvd file and a set >> of vtp XML PolyData files. Each vtp file corresponds to a particular real >> time >> value which are not evenly spaced. I tried to provide the real time >> values via the timestep key >> in the pvd file: >> >> <?xml version="1.0"?> >> <VTKFile type="Collection" version="0.1" byte_order="LittleEndian"> >> <Collection> >> <DataSet timestep="1.23" group="" part="0" file="sp_test0000000.vtp"/> >> <DataSet timestep="2.34" group="" part="0" file="sp_test0002498.vtp"/> >> <DataSet timestep="3.15" group="" part="0" file="sp_test0004496.vtp"/> >> </Collection> >> </VTKFile> >> >> It seems that ParaView expects integer values for the timestep key, >> because >> it loads the files like expected but the time table in the Object >> Inspector -> Information >> tab shows for the above pvd file: >> Index Value >> 0 1 >> 1 2 >> 2 3 >> >> I would be grateful for any help/suggestions. >> >> Thanks, >> Christian Wellmann >> _______________________________________________ >> ParaView mailing list >> [email protected] >> http://www.paraview.org/mailman/listinfo/paraview >> > > > -- > John Biddiscombe, email:biddisco @ cscs.ch > http://www.cscs.ch/ > CSCS, Swiss National Supercomputing Centre | Tel: +41 (91) 610.82.07 > Via Cantonale, 6928 Manno, Switzerland | Fax: +41 (91) 610.82.82 > > > _______________________________________________ ParaView mailing list [email protected] http://www.paraview.org/mailman/listinfo/paraview
