Martin
ERROR: In
/Users/kitware/Berk/ParaView3/VTK/Filtering/vtkDemandDrivenPipeline.cxx,
line 722
vtkCompositeDataPipeline (0x217c7fb0): Input port 1 of algorithm
vtkTemporalStreamTracer(0x1e345e00) has 0 connections but is not optional.
Input 0 should be a time dependent dataset. It is best to use a
TemporalCache before the particle tracer to stop multiple updates for
the same time step. Input 1 should be some seed points.
Ensight -> TemporalCache ->
ParticleTracer
Some Other data eg.line/plane ->
the ignore pipeline time option is provided to get around some animation
issues that used to plague paraview. You should not need it, but the
correct way to use it, is set IgnorePipelineTime to true, then set an
animation keyframe to animate TimeStep from 0->N - the particle tracer
will then use the timestep to generate update times for the Ensight
input, instead of usigin the GUI generated time.
If you are using the particle tracer from prior to 3.4 then you should
switch to a newer one as it is contiunually being improved. I will soon
(months, not days) be checking in a lot of changes which enable it to
handle dynamic meshes better.
JB
I've been looking for information on this and a found a thread which I
think concerns the same problem. In that thread Berk made a patch to fix
this problem.
I also tried to ignore pipeline time, but this doent work. I'm working
with .case files and I want to animate the blood flow in a human heart
using particle tracers. I'm using a Mac with ParaView version 3.4.0.
Thanks for looking into this.
Cheers,
Martin Uppman
_______________________________________________
Powered by www.kitware.com
Visit other Kitware open-source projects at
http://www.kitware.com/opensource/opensource.html
Please keep messages on-topic and check the ParaView Wiki at:
http://paraview.org/Wiki/ParaView
Follow this link to subscribe/unsubscribe:
http://www.paraview.org/mailman/listinfo/paraview
--
John Biddiscombe, email:biddisco @ cscs.ch
http://www.cscs.ch/
CSCS, Swiss National Supercomputing Centre | Tel: +41 (91) 610.82.07
Via Cantonale, 6928 Manno, Switzerland | Fax: +41 (91) 610.82.82
_______________________________________________
Powered by www.kitware.com
Visit other Kitware open-source projects at
http://www.kitware.com/opensource/opensource.html
Please keep messages on-topic and check the ParaView Wiki at:
http://paraview.org/Wiki/ParaView
Follow this link to subscribe/unsubscribe:
http://www.paraview.org/mailman/listinfo/paraview